Operating Instructions 

 

VEK CN1-1 

 

FEIG ELECTRONIC GmbH

 12/11 

15 

5  Safety instructions and Warnings 

  The device may only for the purpose intended by the manufacturer. 

  These operating instructions have to be handed out to every user and kept in an easily accessible 

place. 

  Unacceptable changes as well as the use of spare parts and special features which are not sold or 

recommended by the manufacturer may cause fire, electric shocks and injuries. Such measures do 
therefore lead to nonliability of the manufacturer and a lapse of all warranty claims. 

  The appliance is subject to the manufacturer’s guarantee regulations in the version valid at the time 

of purchase. We cannot be held liable for improper or faulty manual or automatic adjustment of 
parameters resp. improper use of the appliance. 

  Repair work may only be carried out by the manufacturer. 

  Installation, initiation, maintenance, measuring and adjustment of the counting unit should only be 

carried out by electricians with a good knowledge of the rules for prevention of accidents. 

  When handling appliances that get in contact with electricity, the valid VDE-regulations have to be 

observed. In particular, these are: VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711, VDE 0860, 
VDE 0105 as well as the rules for the prevention of accidents and fire VBG4. 

  Before opening the device be assure that power is turned off and re-measure if power is down. 

  If an operation display goes out, this is not a proof that the appliance is disconnected from the mains 

and idle. 

  All labour that is carried out on the appliance as well as its installation has to conform to the national 

as well as the local electric regulations. 

  The user has to make sure that the appliance is installed and operated according to the technical 

rules of the country of installation as well as other regional regulations. Cable dimensions, 
protection, grounding, disconnection, insulation control and excess current protection should be 
especially considered. 

  The gold gladded relay contacts will be destroyed for switching currents higher than 100 mA. Relays 

with such pre-stressed contacts can certainly switch only currents higher than 100 mA.

Содержание Sensors VEK CN1-1

Страница 1: ...Operating Instructions Stand 07 12 11 as ws BES_CN1 1_2011_12_07_GB doc Digital Counter VEK CN1 1 ...

Страница 2: ...oper installation Since errors can never be completely precluded in spite of all our efforts we are always grateful for corrections and suggestions The installation recommendations contained in this guide assume the most favorable circumstances FEIG ELECTRONIC assumes no liability for perfect function of the traffic detector in a foreign system environment Photocopying and reproduction of this gui...

Страница 3: ..._____________________________________________________________ 8 2 3 3 Set Relay Output manually to Free or Occupied ______________________________________________ 8 2 3 4 Display and Counter Reset__________________________________________________________________ 8 2 3 5 Reset all Counter _________________________________________________________________________ 8 2 4 System Menu Installation specif...

Страница 4: ...hicle counter and open space counter 4 digit display Totalize counter 999 9999 4 universal inputs with noise suppression Inputs function individually adjustable for increment decrement or reset 1 reset input 1 relay output 150V 5A for traffic lights and lot full signs or others Output function is adjustable for automatic permanent free permanent occupied Relay is adjustable to normally open or nor...

Страница 5: ...hen the counter reading of the parking spaces is done when the car park is empty so less occupied parking spaces must be counted Vehicles entering the car park will increment the counter input 1 and vehicles leaving the facility will decrement the counter input 2 The counter will activate the output relay whenever the vehicle counter reaches or is higher than the adjusted maximum The output relay ...

Страница 6: ... LED Free Load Current Principle energized Off Used Load Current Principle de energized On Free Rest Current Principle de energized On Used Rest Current Principle energized Off If the operating of the output isn t used the output state can be manually set on always free or always used see 2 3 3 Set Relay Output manually to Free or Occupied 1 6 State Storage during Voltage Breakdown During voltage ...

Страница 7: ...the current menu and state of the setup The buttons have following functionality Button Function M Short Next Menu next digit Cancel settings Mode Long Activate System menu Save changes exit menu Short Display value increment 1 Up Long Display value fast increment Short Display value decrement 1 Down Long Display value fast decrement Two simultaneously Cancel changes back to operating mode The men...

Страница 8: ...t state saved 2 3 4 Display and Counter Reset The inputs can individually count up to 9 999 999 and can individually be displayed or if necessary reset to zero Display State Setting 1234 Normal Operation M 2 x short Cnk1 Input counter 1 M 5 x short Cnk4 Input counter 4 Cnk1 4 1234 alternating display current counter 0 9999 M short continue next menu item current input counter start input counter r...

Страница 9: ...ltaneously or M long End back in normal operation rEL alternating oc on Fr on Output function Normally closed Normally open LoPo alternating off On Power Save Mode off Display on on Display off 2 4 1 Operating Modes switching threshold The digital counter can be set to operating mode OPEN SPACE COUNTING or PASSING VEHICLE COUNTING Two options can be selected by setting the counter threshold to Thr...

Страница 10: ...r 1 sec fast scroll or 3 sec 10 s 100 s 1000 s M short 100 s 10 s 1 s cancel M long Skor save 2 4 3 Counter Level The maximum and minimum range of the total counter can be adjusted using this menu This enables the counter to automatically adjust the total in case the maximum or minimum level reached to prevent an incorrect counter to continue The default is 9999 for upper and 999 for the lower lev...

Страница 11: ...Add Sub rEs no F flashing Change function no F rEs Sub Add Add Sub rEs no F M short cancel M long Skor save Factory default is incrementing for input 1 and 3 and decrementing for input 2 and 4 2 4 5 Output settings The output relay can be adjusted to Normally Open NO or Normally Closed NC Display State Setting 1234 Normal Operation M long SyS S oc M 8 x short rEL relay function rEL alternating Fr ...

Страница 12: ...ry default values using the following procedure Display State Setting Turn off power supply for more than 2 seconds 1234 flashing Return after power failure Press two buttons simultaneously Err Err flashing System error M long Skor reset to factory default 0000 flashing factory default M short cancel restart without factory default settings After a reset to factory default values all parameters ar...

Страница 13: ...puts No galvanic isolation galvanic isolation inside counter Attention Terminal C at the front side near to the terminals of the supply voltage can only be used with internal Power Supply as an alternative connection to terminal Com Terminal C mustn t be wired if external Power Supply is used Inputs of several counter units can be connected in parallel as follows Power Supply Input power Attention...

Страница 14: ...24 V AC DC 10 Power Consumption max 2 W Operating Temperature 20 C to 70 C Storage Temperature 40 C to 70 C Humidity max 95 non condensing Counting range Total 999 to 9 999 0 9 999 999 for each counting input Inputs Photo Coupler common anode minus switching 4 Inputs 1 Reset input Minimum input time 50 ms Input current ca 5 mA at 12 V ca 10 mA at 24 V Relay output Form C max Current Rating AC 250 ...

Страница 15: ...s with a good knowledge of the rules for prevention of accidents When handling appliances that get in contact with electricity the valid VDE regulations have to be observed In particular these are VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 VDE 0860 VDE 0105 as well as the rules for the prevention of accidents and fire VBG4 Before opening the device be assure that power is turned off and re measure i...

Страница 16: ... Menu item Setting Program Version Vers __________ read only S oc Threshold 0 9 999 Value __________ HYS Counter Hysteresis 1 250 Value __________ SkP Upper Counter Threshold 0 9 999 Value __________ SkP_ Lower Counter Threshold 0 999 Value __________ inP1 Input Function 1 Add increment Sub decrement rEs reset no F no function inP2 Input Function 2 Add increment Sub decrement rEs reset no F no fun...

Отзывы: