Installation Manual ID RWA02.ABCD-A / -B -AL / -BL
FEIG ELECTRONIC GmbH
Page 21 of 26
E N G L I S H
5. Installation:
Reader ID RWA02.ABCD
may not be installed directly on conducting materials such as metal
surfaces, metal grids (reinforced walls), or other metalliferous surfaces. These surfaces influence
the magnetic field and therefore reduce the reader range. Nevertheless, when the reader must be
installed to a metalliferous surface a minimum distance of 3 cm must be respected.
The
distance to other readers should be minimum 30 cm.
5.1 ID RWA02.ABCD-A / -B:
The reader is designed to be installed directly on common switch boxes. It can be screwed on
such a switch box with the enclosed screws.
For installations on metal surfaces you can order the surface frame ID APG-A by FEIG ELEC-
TRONIC.
After installation and the connection of all clamps but before fixing the adhesive label, the
correct function of the reader must be tested !
5.2 ID RWA02.ABCD-AL/ -BL:
The Reader is designed to be installed into a casing. The installation place should be selected
carefully - the transponder should be hold area-parallel to the antenna.
The distance between the reader antenna to conducting materials should be of minimum 3 cm.
Otherwise, the reading range will be decreased.