5. Protocols for Reader Control
5.1. [0x52] Baud Rate Detection
This protocol serves to determine the actual baud rate of the Reader’s asynchronous interface.
Host
→
Reader
1
2
3
4
5,6
6
COM-ADR
[0x52]
0x00
CRC16
Host
←
Reader
1
2
3
4
5,6
6
COM-ADR
[0x52]
0x00
CRC16
Note:
•
The return protocol will only be sent if the inquiry is executed with the baud rate and actual
parity of the Reader.
5.2. [0x55] Start Flash Loader
This protocol starts the internal Flash Loader in the Reader to perform a firmware update.
Please read the corresponding update description.
Host
→
Reader
1
2
3
4,5
5
0x00
[0x55]
CRC16
Host
←
Reader
1
2
3
4
5,6
6
0x00
[0x55]
0x00
CRC16
Note:
•
This command is only available if the correct COM-ADR of the Reader is used.
•