H90400-0e-ID-B.doc
1. Data Transmission between OBID
®
i-scan ID ISC.M02.M8-B and Host
The ISOHost mode is used for data transmission between OBID
®
i
-scan
Readers and the host (termi-
nal, PC). The
ISO15693 Host Commands
are used for the data exchange between Transponder and
host, whereas the
Configuration Commands
and the
Control Commands
serves for adapting the
Reader parameters to the individual range of applications. The following chart shows which method of
data transmission is supported by which interface:
asynchronous interface
(RS232 / RS485)
Control Commands
√
ISO15693 Host Commands
√
Configuration Commands
√
1.1. Configuration Commands and Control Commands
This method of data transmission is used for Reader configuration and the diagnosis via the asyn-
chronous interface.
The Reader-configuration parameters will be stored in the Readers non retentive memory (RAM). After
power up, the Reader reads the default configuration out of the flash memory (EEPROM).
The Reader control is immediately processed and the response from the Reader contain status or
data information of the control command.
Host (Terminal / PC / ....)
Reader
parameter- / control command
→
parameter received and stored / control
command processed
yes
no
←
status /
data
error status
←