OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 42 of 174
H90692-16e-ID-B.doc
3.10. CFG10: General System Parameters
The parameters of the CFG10 configuration block contain general system settings.
Byte
0
1
2
3
4
5
6
Contents
SYS-MODE
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x04
0x00
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
BUFFER-
INFO-MODE
Default
0x00
SYS-MODE
1
:
The
SYS-MODE
register enables the different operation modes of the Reader.
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ACOLL
OP-Mode
OP-Mode:
b00 ISO-Host Mode
b01 Buffered Read Mode
b10 Scanner Mode
ISO-Host Mode:
This bit combination activates the ISO15693 Host Mode. If the ISO15693
Host Mode is enabled the ISO15693 Host commands will be available.
Buffered Read Mode:
This bit combination activates the Buffered Read Mode. If the Buffered Read
Mode is enabled there are no ISO15693 Host commands available.
Scanner Mode:
This bit combination activates the Scanner Mode. In the Scanner Mode the
Reader sends the Transponder data automatically after their detection.
If the
Scanner Mode is enabled there are no ISO15693 Host commands available.
Note:
•
Changing of OP-Mode only becomes effective after writing / saving configuration
block CFG10 to EEPROM and reset of the Reader.