2.4 Activating Buffered Read Mode
„Buffered Read Mode“ is the normal operating mode of the Reader. Here the tags are read at
maximum speed and the information is stored in the Reader’s circular buffer. This data can be read
by the host.
To activate „Buffered Read Mode“ proceed as follows:
Step
Action
Note
1
Select „Configuration“
2
CFG11:
Read Mode –Read Data
TR.DATA
Serial Number
Time
Date
Ant Store
3
Set by clicking on “Write”
4
CFG12: Read Mode-Filter
VALID-TIME
e.g. 55 x 100 ms
5
Set by clicking on “Write”
6
CFG1:
Interface and Mode
Select „Buffered Read
Mode“.
7
Set by clicking on “Write”