OBID
i-scan
®
Montage / Installation
ID ISC.MRU102
FEIG ELECTRONIC GmbH
Seite 29 von 42
M20110-1de-ID-B.doc
12
Connections
Depending on the reader variant different connectors are available. Figure 3: Connection overview
displays the arrangement and the Table 2: Connectors shows which connector can be used for the
different interface cable.
Figure 2: Connection overview
Connector
Description
ANT 1
Antenna terminal ANT 1 (Impedance 50Ohm)
X1
Power supply 12 - 24VDC
X3
USB Interface
X4
10/100Tbase Ethernet interface with RJ-45 (PoE)
Table 2: Connectors