6.3 Configuration and Test
To activate the People Counters the following settings hast o be done.
Set additional the Jumpers JP1,2 and 5 at X700 of Reader ID ISC.LRM2000-A to configure the
RS485. Fig. 2 (see also manual M51001-2de-ID-B , page 43 and 44)
Fig. 2 Jumper settings RS485 Interface
If you want to use several People counters at gate with 3 to 7 aisles, you have to set the corres-
ponding Busaddress. The Busaddress could be set by the Dip-Switch at the People Counter
Board. See Fig. 3. At one reader maximum 3 People Counter (Busaddress 1-3) could be operated.
Fig. 3 Position of Dip Switch at People Counter Board
Table 7 Setting the bus address of People Counter