4.3 Drilling the Mounting Holes
If the position of the antennas has been marked or determined a hole template, can be used to
mark and drill the mounting holes and the holes for the cable entry. The dimensions are shown in
Fig. 7:
Fig. 7: Floor plate dimensions
All dimensions are in mm with general tolerance to ISO 2768 m (middle).
The size and type of the screw anchors depends considerably on the strength of the base or floor.
The anchors should be capable of withstanding a permissible load of at least 5 kN per anchor for
all load directions (e.g. for concrete floor Hilti HVA anchors with HAS-(E) M8 threaded rod or Hilti
HIS-
N M8 (5/16”) threaded inserts). The size of the mounting holes in the antenna is 10 mm (.39”).
The length of the anchors or bolts should be selected such that they extend at
least 50 mm (2.0”)
and a maximum of 65 mm (2.6”) from the floor.
Please follow the mounting instructions of the anchor manufacturer!
Two cable openings are provided for the necessary connection cable (see Fig. 7). The cable
openings are dimensioned such that up to 10 cables having a diameter of 6 mm can be passed
through each opening.
We recommend routing the antenna cables through the cable opening on the Multiplexer side. All
other cables such as the supply voltage and synchronization cable should be routed through the
cable opening on the Reader side.