OBID i-
scan
®
Installation
ID ISC.ANT1700/740-SLA/-SLB
FEIG ELECTRONIC GmbH
Page 31 of 66
M00210-2e-ID-B.doc
5.2.7 Tuning the Gate Antenna with Multiplexer
Before tuning the gate antenna, you must quit the ISOStart software. Then the gate can be tuned
as follows:
Step
Action
Note
1
Start “DATuningTool” software
2
Select “Detect Reader...”.
In the „Detect Reader“ window
select the interface (COM-Port
1, BusAdr. 0) and then click
on “Detect”.
3
Use „Settings“ to enter the
configuration:
Single Mode,
Number of Antennas 4
Click on “with Multiplexer“
Number of Tuning Iterations 3
4
Activate „Start Tuning“ and
wait until the tuning process is
finished.
...
...
5
The tuning status is displayed
after each tuning pass.
After successful tuning both
antennas are shown in green.
6
If this does not succeed on
the first try, start the process
again by clicking on „Start
Tuning“
After successful tuning, close the DATuningTool.