OBID i-
scan
®
Installation
ID ISC.ANT1700/740-SLA/-SLB
FEIG ELECTRONIC GmbH
Page 49 of 66
M00210-2e-ID-B.doc
6.2 Installation ID ISC.ANT.GPC-E
Content of the ID ISC.ANT.GPC-E
1. 1 piece Radar connection cable
2. 1 piece Radar module
3. 2 piece Jumper
4. 2 piece spilt rivet 3,0mm
5. 1 piece cable-clip
Step
Action
Note
1.
Attention !!
Note: Do not touch the an-
tenna surface of the Radar
module to avoid damaging
the electronic components
and soiling.
2.
Set sensitivity of Radar
sensor by setting jumper J1
and J2.
Sensitivity:
JP1+2 open: Low
JP1 closed: Middle
JP2 closed: High
JP1+2 closed: Very high
Recommended Sensitivity:
High
1.
2.
4.
3.
5.