7. Safety Instructions / Warning - Read before start-up! 

 

The device may only be used for the intended purpose for which it is designed for. 

 

The operation manual should be conveniently kept available at all times for each user. 

 

Unauthorized changes and the use of spare parts and additional devices which have not 
been  sold  or  recommended  by  the  manufacturer  may  cause  fire,  electric  shocks  or 
injuries. Such unauthorized measures shall exclude any liability by the manufacturer. 

 

The liability-prescriptions of the manufacturer in the issue valid at the time of purchase 
are  valid  for  the  device.  The  manufacturer  shall  not  be  held  legally  responsible  for 
inaccuracies,  errors,  or  omissions  in  the  manual  or  automatically  set  parameters  for  a 
device or for an incorrect application of a device. 

 

Repairs may only be executed by the manufacturer. 

 

Installation,  operation,  and  maintenance  procedures  should  only  be  carried  out  by 
qualified personnel. 

 

Use of the device and its installation must be in accordance with national legal 
requirements and local electrical codes. 

 

When working on devices the valid safety regulations must be observed. 

 

Special advice for carriers of cardiac pacemakers: 
Although this device doesn't exceed the valid limits for electromagnetic fields you 
should keep a minimum distance of 25 cm between the device and your cardiac pace-
maker and not stay in an immediate proximity of the device respective the antenna for 
some time. 

 

8. Characterization ID CPR50.10-E 

The ID CPR50.10-E is a member of the OBID

 

classic-pro

 reader family and supports transponder 

chips according ISO/IEC 14443 type A and type B as well as transponder chips according ISO/IEC 
15693 and is able to communicate with NFC devices. 

Because of its Ethernet interface according 10BASE-T / 100BASE-TX standard the ID 
CPR50.10-E is well suited for integration in an existing LAN environment with CAT-5 cable infra-
structure.  

Alternatively either a power over ethernet (PoE) power supply (according to IEEE802.3af) or an 
external DC power supply can be used. 

The ID CPR50.10-E can work in ISO-Host mode (polling) or in notification mode which reduces the 
necessary data traffic with the reader to a minimum. In notification mode the host will be informed 
by a notification message if a transponder was detected by the reader and can start the further 
data exchange with this transponder if required.The remote I/O-board (ID CPR.I/O-B) can be con-
nected to the ID CPR50.10-E to have one relay output and 2 digital inputs. 

Содержание ID CPR50.10-E

Страница 1: ...ON final public B 2018 09 05 M90701 7de ID B doc ID CPR50 10 E RFID Reader for ISO IEC14443 A B NFC and ISO IEC15693 with Ethernet Interface RFID Access Control Terminal with Ethernet Interface deutsc...

Страница 2: ...Identification Montage ID CPR50 10 E FEIG ELECTRONIC GmbH Seite 2 von 31 M90701 7de ID B doc D E U T S C H deutsche Version ab Seite 3 english version from page 18 E N G L I S H...

Страница 3: ...ler trotz aller Bem hungen nie vollst ndig vermeiden lassen sind wir f r Hinweise jederzeit dankbar Die in diesem Dokument gemachten Installationsempfehlungen gehen von g nstigsten Rahmenbedingun gen...

Страница 4: ...onales Zubeh r 6 3 Montage und Anschluss 7 3 1 Anschluss des Adapter Board 9 3 1 1 LSA Anschluss X2 f r TCP IP Verbindung 9 3 1 2 Anschluss ber PoE Netzteil 10 3 1 3 Anschluss einer externe Spannungsv...

Страница 5: ...g ltigen Fassung F r eine ungeeignete falsche manuelle oder au tomatische Einstellung von Parametern f r ein Ger t bzw ungeeignete Verwendung ei nes Ger tes wird keine Haftung bernommen Reparaturen d...

Страница 6: ...cation Mode sendet der Reader automatisch die gelesenen Transponderdaten an den Host PC dieser kann dann einen weiteren Datenaustausch initiieren falls notwendig An den ID CPR50 10 E kann das externe...

Страница 7: ...ausreichender Abstand zwischen Leser und Metalloberfl che hergestellt ist Beim Einbau des Readers in einen Metallrahmen ist darauf zu achten dass ein Mindest abstand vom ca 25mm zum Reader eingehalte...

Страница 8: ...erteil auf der Wand verschrauben Montagerichtung TOP beachten siehe Kapitel 3 Montage Geh useoberteil gerade auf das Geh useunterteil aufstecken und einrasten Stiftleiste X1 der Leserelektronik sauber...

Страница 9: ...l auf der LSA Anschlussleiste ist ein entspre chendes LSA Auflegewerkzeug punch down tool zu verwenden Es gibt bei CAT 5 zwei Belegungen EIA TIA T568A und EIA TIA T568B Die entsprechende Farb codierun...

Страница 10: ...R50 10 E Door Contact UNITRONIC CY PiDY LiYCY TP 2 x 2 x 0 25 mm 2 Wir empfehlen die Versorgung des T r ffners ber ein separates Kabel zu f hren Verdrillte Paare GND VCC RxD TxD Abbildung 7 ID CPR50 1...

Страница 11: ...Kabel zu f hren Verdrillte Paare GND VCC RxD TxD Abbildung 8 ID CPR50 10 E mit ID CPR I O B und 24 VDC Versorgung X3 ID CPR50 10 E 1 Externe 24 V DC 2 Externe GND Tabelle 2 Anschluss f r externe Spann...

Страница 12: ...m paarweise verdrillt 6 GND D 2 VCC 5 VDC 5 VCC 3 RxD Interface Max 5 m paarweise verdrillt 4 OUT 4 TxD 3 IN 5 IN1 Digitaler Eingang 1 T r Kontakt 6 IN2 Digitaler Eingang 2 7 Relais NO T r ffner 8 Re...

Страница 13: ...agerung 20 C bis 55 C 40 C bis 85 C relative Luftfeuchte 95 nicht betauend Antenne intern ca 70 x 70 mm Betriebsfrequenz 13 56 MHz Sendeleistung 250 mW 2 dB RF Interface ISO14443 A ISO14443 B NFC 1 IS...

Страница 14: ...D E U T S C H 4 1 Abmessungen X1 1 84 2 mm 84 2 mm 60 0 mm 60 0 mm 77 7 mm 56 8 mm 60 0 mm 28 4 mm 28 4 mm 77 7 mm Abbildung 10 Unterputzgeh use Befestigungsmasse Abbildung 11 Aufputzadapter Befestig...

Страница 15: ...eit Niederspannung Human Exposure EN 60950 EN 50364 Umwelt RoHS 2002 95 EC WEEE 2002 96 EC 5 1 Europa CE Hiermit erkl rt FEIG ELECTRONIC GmbH dass der Funkanlagentyp ID CPR50 10 der Richtlinie 2014 53...

Страница 16: ...ehe Kapitel 3 Montage und Anschluss 2 Einen 2 mm Jumper auf die Steckkontakte B2 stecken und den Reader wieder mit Spannung versorgen Geh useoberteil wieder auf die Adapter Platine stecken 3 Ein alter...

Страница 17: ...Identification Montage ID CPR50 10 E FEIG ELECTRONIC GmbH Seite 17 von 31 M90701 7de ID B doc D E U T S C H...

Страница 18: ...avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for pe...

Страница 19: ...1 Connections 24 9 1 1 LSA Connection X2 for TCP IP Interface 24 9 1 2 Connection with PoE Supply 25 9 1 3 Connection with External Powered Supply 26 9 1 4 Connection of the extension I O Board ID CP...

Страница 20: ...id safety regulations must be observed Special advice for carriers of cardiac pacemakers Although this device doesn t exceed the valid limits for electromagnetic fields you should keep a minimum dista...

Страница 21: ...x 3 x 8 mm Torx T10 for closing the housing 2 x Thread cutting screws 3 2 x 15 mm for mounting the surface adapter 2 x Thread cutting screw 3 2 x 25 mm for wall mounting 1 x Installation instruction 8...

Страница 22: ...in order to keep the minimal distance If the device is installed in a metal frame it must be ensured that a minimum distance of 25 mm is observed to the metal frame Closed metal frame loop must be in...

Страница 23: ...rew bottom part of casing to selected surface Take care about the mounting direction TOP Put the casing upper part straight onto its bottom part and snap it in see Fig 4 Insert the pin board X1 of the...

Страница 24: ...applying the CAT5 cable on to the LSA connector a special LSA punch down tool must be used There are existing two different ways for the connection of a CAT5 cable EIA TIA T568A and EIA TIA T568B The...

Страница 25: ...t Ethernet ID CPR IO ID CPR50 10 E Door Contact UNITRONIC CY PiDY LiYCY TP 2 x 2 x 0 25 mm 2 We recommend using a separate cable for the supply of the Door opener Twisted pair GND VCC RxD TxD Fig 7 ID...

Страница 26: ...eparate cable for the supply of the Door opener Twisted pair GND VCC RxD TxD Fig 8 ID CPR50 10 E with ID CPR I O B and external 24 VDC power supply X3 ID CPR50 10 E 1 External 24 V DC 2 External GND T...

Страница 27: ...und Max 5 m twisted paired 6 GND D 2 VCC 5 VDC 5 VCC 3 RxD Interface Max 5 m twisted paired 4 OUT 4 TxD 3 IN 5 IN1 Digitaler Input 1 Door Contact 6 IN2 Digitaler Input 2 7 Relay NO Door Opener 8 Relay...

Страница 28: ...ded CAT 5 cable Temperature range Operation Storage 20 C to 55 C 40 C to 85 C Relative air humidity 95 non condensing Antenna internal approx 70 x 70 mm Operating frequency 13 56 MHz RF Transmitting P...

Страница 29: ...7de ID B doc E N G L I S H 10 1 Dimensions X1 1 84 2 mm 84 2 mm 60 0 mm 60 0 mm 77 7 mm 56 8 mm 60 0 mm 28 4 mm 28 4 mm 77 7 mm Fig 10 Concealed casing Fixing dimensions Fig 11 Surface adapter dimens...

Страница 30: ...following FCC caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment NOTE This equipment has been...

Страница 31: ...e party responsible for compliance could void the user s authority to operate this equipment 12 Configuration Reset Factory setting With the help of the jumper B2 it is possible to set the reader back...

Отзывы: