9.1.3. Connection with External Powered Supply
The power supply via an external power supply is not necessary if the reader is powered via PoE
power supply. In that case the connection X3-1 and X3-2 are not used.
Ethernet
ID CPR.IO
ID CPR50.10-E
Door Contact
+ -
UNITRONIC CY PiDY / LiYCY (TP)
2 x 2 x 0,25 mm
®
2
We recommend using a separate
cable for the supply of the
Door opener!
Twisted pair:
- GND / VCC
- RxD / TxD
Fig. 8 ID CPR50.10-E with ID CPR.I/O-B and external 24 VDC power supply
X3
ID CPR50.10-E
1
Ex 24 V DC
2
External (-) GND
Table 2 Connection for the external power supply on X3
NOTICE:
The reader has to be supplied by a limited power supply (e.g. NEC Class 2/LPS power
sup-ply) according EN 62368-1 chapter Q.1, only.Use only regulated power supplies.
Reversing the polarity of the supply voltage may destroy the device.
Supply voltages outside the specifications may destroy the device.
If switching power supplies are used, be sure that there is adequate filtering.