background image

 

  If you swallow fuel by mistake, if you inhale fuel vapours or if you get drops of fuel in your eyes, 

see a doctor immediately. If a certain quantity of fuel is spilt on your skin or clothing, wash or 
change your clothes. 

  Always stop the motor of the generator when filling it with fuel.  

  Never fill the fuel tank while smoking or near a naked flame. 

 

Make sure you don’t spill fuel on the motor and the exhaust grille of the generator during filling 
with fuel. 

  Keep the fuel in an appropriate recipient and sheltered from any sources of fire. 

  Carry out filling in a safe place, and slowly open the fuel cap to release the pressure which has 

built up inside the tank. Wipe up any drops of petrol that have spilled before starting the motor. 

  To prevent fire, move the generator at least 4 metres away from the area for filling with fuel. 

  Make sure that the fuel cap is tightly closed before starting. 

  Do not keep petrol in the tank for a long time. 

  While using or transporting the generator, make sure you keep the generator upright, 

otherwise the fuel may escape from the carburettor or the fuel tank. 

ELECTRICAL SAFETY 

  Before each use ensure that the load to be connected does not exceed the power of the 

current produced by the generator. 

To avoid electric shock, you must follow the following instructions: 

  Do not touch the generator with wet hands. 

  Do not run the generator under rain or snow. 

  Do not run the generator near water. 

  Connect the generator to earth. Use a sufficiently thick conductor for the earth wire. 

  Do not operate the generator in parallel with another generator. 

  If using electrical extensions, make sure that they are sufficiently thick to transport the current 

and that they are used correctly. 

 

The connection of a generator used for auxiliary power to the electrical installation of a 

building must be performed by a qualified electrician, and in conformity to the provisions of the 
applicable laws and norms in the field of electricity. Incorrect connections will cause leakage of 
the current from the generator into the lines of the public electricity company. Such leakage 
could electrocute the workers of the public electricity company working on the network or other 
persons in contact with the line during a power cut. Also, when the public power supply is re-
established, the generator can explode, catch fire or generate fires in the building’s electrical 
installation. 

Before connecting electrical devices to the generator, make sure that their voltage 

specifications and frequency of functioning correspond to the technical characteristics of the 
generator. There may be damage if the device connected is not designed to function with a 
voltage tolerance of +/- 10% or a frequency tolerance of +/- 3 % compared with those of the 
generator. 

 
PROTECTION OF THE ENVIRONMENT 

  You must periodically check the silencer (Before doing this, switch off the generator and let it 

cool completely). A damaged silencer increases noise. 

  Do not throw motor oil into the drains but deposit it at a collection point set up for that purpose. 

  The fuel for this machine is combustible and explosive. After stopping the machine, you must 

handle the remaining fuel correctly and meet local environmental requirements. 
 

Содержание FG8500RS

Страница 1: ...ORIGINAL INSTRUCTIONS EN GASOLINE GENERATOR FG8500RS FG8500ES INSTRUCTION MANUAL CAUTION Read the instructions before using the machine...

Страница 2: ...12 5 GENERATOR USE 14 6 PRE OPERATION CHECK 17 7 STARTING STOPPING THE ENGINE 19 8 MAINTENANCE 19 9 TRANSPORTING AND STORAGE 22 10 TROUBLESHOOTING 24 11 WIRING DIAGRAM 26 12 SPECIFICATIONS 28 13 EC D...

Страница 3: ...as it runs Use safety equipment Wear protective gear such as an anti dust mask non slip safety shoes a helmet or hearing protection Stay vigilant watch what you are doing and show good sense when you...

Страница 4: ...ible and easily ignited Do not refuel during operation Do not refuel while smoking or near naked flames Do not spill fuel Some parts of the internal combustion engine are hot and may cause burns Pay a...

Страница 5: ...arth wire Do not operate the generator in parallel with another generator If using electrical extensions make sure that they are sufficiently thick to transport the current and that they are used corr...

Страница 6: ...not dispose of old appliances with domestic rubbish Add engine oil Guaranteed sound power level No naked flames WARNING Make sure there are no spills or fuel leaks Ground connection Stay away from the...

Страница 7: ...dd engine oil before using 2 COMPONENT IDENTIFICATION NOTE Diagrams may vary according to the types This gasoline generator intended used for out door site where the power needed less than power show...

Страница 8: ...8 FG8500RS panel and rating label FG8500ES panel and rating label...

Страница 9: ...een replaced Using an incomplete or damaged product represents a hazard to people and property 3 Ensure that you have all the accessories and tools needed for assembly and operation 3 2 SCOPE OF THE D...

Страница 10: ...e generator Assemble the axis and wheel on one side of the support Assemble the axis and wheel on other side of the support 3 4 FOOT PAD Keep the tool upside down Localise the two holes on the bracket...

Страница 11: ...11 3 5HANDLE Press the button then rolling over the handle Screw the support with screws and nuts...

Страница 12: ...witch and wait 10 seconds before trying to start again 4 2 RECOIL STARTER To start the engine pull the starter grip lightly until resistance is felt then pull briskly NOTICE Do not allow the starter t...

Страница 13: ...tch the generator power ON or OFF 4 6 GROUND TERMINAL The generator ground terminal is connected to the panel of the generator the metal non current carrying parts of the generator and the ground term...

Страница 14: ...ound is not connected to the AC neutral wire If the generator is tested by a receptacle tester it will not show the same ground circuit condition as for a home receptacle Special Requirements There ma...

Страница 15: ...cuit breaker 5 5 DC OPERATION DC Terminals The DC terminals may ONLY be used for charging 12 volt automotive type batteries The terminals are colored red to identify the positive terminal and black to...

Страница 16: ...y cable from the generator negative terminal 3 Disconnect the other end of the negative battery cable from the battery negative terminal 4 Disconnect the positive battery cable from the generator posi...

Страница 17: ...dipstick clean 2 Check the oil level by inserting the dipstick into the filler neck without screwing it in 3 If the level is low add the recommended oil to the upper mark on the dipstick 6 2 FUEL RECO...

Страница 18: ...to help meet clean air standards If you use an oxygenated fuel be sure its pump octane rating is 86 or higher Ethanol ethyl or grain alcohol Gasoline containing more than 10 ethanol by volume may caus...

Страница 19: ...d be recharged 1 When the engine starts allow the engine switch to return to the ON position 2 Turn the choke lever or push the choke rod to the OPEN position as the engine warms up 7 2 STOPPING THE E...

Страница 20: ...ion or use it in unusually wet or dusty conditions consult your servicing dealer for recommendations applicable to your individual needs and use 8 2 TOOL KIT The tools supplied with the generator will...

Страница 21: ...flash point solvent Allow the element to dry thoroughly 3 Soak the element in clean engine oil and squeeze out the excess oil The engine will smoke during initial start up it too much oil is left in...

Страница 22: ...gine cool before transporting or storing the generator Take care not to drop or strike the generator when transporting Do not place heavy objects on the generator Before storing the unit for an extend...

Страница 23: ...several revolutions to distribute the oil then reinstall the spark plug 4 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both...

Страница 24: ...gnite To check 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinde...

Страница 25: ...circuit breaker ON Check the electrical appliance or equipment for any defects YES NO Take the generator to an authorized generator dealer NO DEFECTS Replace the electrical appliance or equipment Tak...

Страница 26: ...26 11 CIRCUIT DIAGRAM...

Страница 27: ...27...

Страница 28: ...920g kW h Lube Oil capacity L 1 1 L Sound pressure level LpA 72 3 dB A K 2 80 dB A Measured sound power level LwA 92 0 dB A K 2 80 dB A Guaranteed sound power level 95 dB A Generator SET AC out put Vo...

Страница 29: ...designated below Gasoline Generator Model FG8500RS FG8500ES Serial number 20221111977 20221112106 20221112114 20221112251 Complies with the provisions of the Directive machinery 2006 42 CE and nation...

Страница 30: ...ibed in the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifications without notice Consequently the product may be different from the inf...

Страница 31: ...t is available before dropping off the machine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the servic...

Страница 32: ...oduct during the time necessary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate b...

Страница 33: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC 2022...

Отзывы: