4.4 CHOKE LEVER
The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened
and closed by operating the choke lever or choke rod manually. Move the lever or the rod to the
CLOSE position to enrich the mixture.
4.5 CIRCUIT BREAKER
The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of
the generator at the receptacle. If the circuit breaker is switched OFF automatically, check that the
appliance is working properly and does not exceed the rated load capacity of the circuit before
switching the circuit breaker ON again. The circuit breaker may be used to switch the generator
power ON or OFF.
4.6 GROUND TERMINAL
The generator ground terminal is connected to the panel of the generator, the metal non-current
carrying parts of the generator, and the ground terminals of each outlet socket. Before using the
ground terminal, consult a qualified electrician, electrical inspector or local agency having jurisdiction
for local codes or ordinances that apply to the intended use of the generator.
4.7 OIL ALERT SYSTEM
The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in
the crankcase. Before the oil level in the crankcase can fall below a safe limit, the oil alert system will
automatically shut down the engine (the engine switch will remain in the ON position). The oil alert
system shuts down the engine and the engine will not start. If this occurs, first-check engine oil.
Содержание FG8500RS
Страница 8: ...8 FG8500RS panel and rating label FG8500ES panel and rating label...
Страница 11: ...11 3 5HANDLE Press the button then rolling over the handle Screw the support with screws and nuts...
Страница 26: ...26 11 CIRCUIT DIAGRAM...
Страница 27: ...27...
Страница 33: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC 2022...