mr
.
steam
®
AROMAFLO Operation & Installation
__________________________________________________________________
9
"X" indicates switch position.
In this illustration the switch is "On".
Adjusting the Amount of Oil Delivery
Programming
Programming Switch is located
inside the metering pump.
1.
After switching off power
supply, open cover of the
metering pump
2.
Program the switches to
desired settings
3.
Close cover of the metering
pump
4.
Reconnect the power
The AromaFlo is factory set to
deliver 0.07 ounces (VOLUME) of
Mr.Steam essential oil every 1
minute 15 seconds (INTERVAL).
Increase and/or decrease the
VOLUME and INTERVAL settings
in any combination to adjust the
flow of essential oil. Use the
settings guide provided.
Contact the Mr.Steam Technical
Service Department at (800) 76
STEAM (East coast) or (800) 72
STEAM (West coast) for assistance
or additional information.
VOLUME
STAND-BY
Switch S1 (Top)
Switch S2 (Bottom)
________________________________________________
0.018 Oz
________________________________________________________
0.035 Oz
2 min 30 sec
________________________________________________________
0.053 Oz
3 min 45 sec
________________________________________________________
*0.070 Oz
5 min
________________________________________________________
0.088 Oz
6 min 15 sec
________________________________________________________
0.106 Oz
7 min 30 sec
________________________________________________________
0.123 Oz
8 min 45 sec
________________________________________________________
*Factory Setting
Switch off power before opening
cover to prevent electric shock!
1
2
3
4
D
E
C
R
E
A
S
E
IN
C
R
E
A
S
E
AMOUNT
OF OIL
D
E
C
R
E
A
S
E
IN
C
R
E
A
S
E
AMOUNT
OF OIL
Programming
Switch
ON
OFF
ON
OFF
X
X X X X
The metering pump
has been factory set to deliver a suitable
amount of aromatic oil into a typical
sized steam room.
PLEASE CONTACT
THE MR.STEAM TECHNICAL SERVICE
DEPARTMENT BEFORE CHANGING
THIS SETTING. Increasing the settings
may introduce excessive concentration
of oil into the steam room, resulting in a
health hazard.
*1 min 15 sec
*0.070 Oz
Factory “Interval” Setting
Factory “Volume” Setting
Location of
Programming Switch
Circuit board inside metering pump
Note: Switch 3 should not be adjusted
1
2
3
4
X X X X
1
2
3
4
ON
OFF
ON
OFF
X
X X X
1
2
3
4
X
X X X
1
2
3
4
ON
OFF
ON
OFF
X
X
X X
1
2
3
4
X
X
X X
1
2
3
4
ON
OFF
ON
OFF
X X
X X
1
2
3
4
X X
X X
1
2
3
4
ON
OFF
ON
OFF
X X
X
X
1
2
3
4
X X
X
X
1
2
3
4
ON
OFF
ON
OFF
X
X
X
X
1
2
3
4
X
X
X
X
1
2
3
4
ON
OFF
ON
OFF
X
X X
X
1
2
3
4
X
X X
X
CAUTION
!
WARNING
!
Warning Sign
(not actual size)
This room is equipped with an aromatic
oil dispensing system. Leave room
immediately if you have any adverse or
allergic reactions, including difficulty
breathing or eye, nasal, throat.
Sussman-Automatic Corp.
3-20 34th Street, Long Island City NY 11101
1-800-76 STEAM
WARNING!
PUR 100381 3/02