MAINTENANCE

Maintenance of Metering Pump

IMPORTANT NOTE:

Clean the suction and pressure valves

of deposits every 6 months, more frequently if necessary.

Maintenance of Suction Valve

1. Disconnect power supply.
2. Unscrew the suction end nut and remove the suction

hose.

3. Unscrew suction valve. Carefully remove the valve spring

with the pressure bolt and the valve plate.

4. Rinse suction valve, valve spring, pressure bolt and valve

plate with clear water. Remove deposits using a moist
cloth.

5. Clean the spring guide in the pump head and the valve

seat in the suction valve by means of a moist cloth.
Remove deposits and debris.

6. Position the valve plate in the valve seat and place the

valve spring with the pressure bolt in the center of the
valve plate.

7. Carefully screw the suction valve with the valve spring

into the pump head and tighten by HAND only.

8. Install the suction hose, see page 4, “Installation of

Pressure Hose.”

IMPORTANT NOTE:

The valve plate must be level in the pump head!

Maintenance of Pressure Valve

1. Disconnect power supply.
2. Unscrew pressure end nut and remove pressure hose.
3. Unscrew pressure valve. Cautiously remove the valve spring

with the pressure bolt and the valve plate.

4. Rinse pressure valve, valve spring, pressure bolt and valve

plate with clearwater. Remove deposits using a moist cloth.

5. Clean the valve seat in the pump head and the spring guide

in the pressure valve with a moist cloth and remove
deposits.

6. Position the valve plate in the valve seat of the pump head

and place the valve spring with the pressure bolt in the cen-
ter of the valve plate.

7. Cautiously insert the pressure valve with the valve spring

into the pump head and tighten it by HAND only.

8. Install the pressure hose, see page 4, “Installation of

Pressure Hose.”

IMPORTANT NOTE:

The valve plate must be level within the

pump head. Insert the valve spring without off-setting the
pressure valve spring guide.

Pressure End Nut

Pressure Valve

Valve Spring with
Pressure Bolt

Valve Plate

Pump Head

Valve Spring with
Pressure Bolt

Valve Plate

Suction Valve

Suction End Nut

Figure 9

Содержание mr. steam AromaFlo

Страница 1: ...mr steam Feel Good Inc AromaFlo Installation Operation Manual...

Страница 2: ...struc tions you will notice warning and caution symbols This blocked information is important for the safe and efficient installation and operation of this generator These are types of potential hazar...

Страница 3: ...umps outdoors 3 Do not install AromaFlo Pumps in a location where water could freeze 4 Do not install AromaFlo Pumps near flammable or corro sive materials and chemicals Installation in areas having h...

Страница 4: ...omaFlo box 2 Unscrew the cover from the Mr Steam scent container and discard 3 Insert the suction hose with the open end from below through the hole in the container cover see Fig 3 4 Insert the filte...

Страница 5: ...mp line cord 120V 90 T Atomizer nozzle Pressure hose AromaFlo pump Suction hose Scent Container Steam solenoid with electrical box Typical MrSteam Commercial steam generator Electrical connection to D...

Страница 6: ...s on 120VAC 50 60hZ power supply Refer to nameplate on AromaFlo pump If the power cord of the meter ing pump is damaged it must be replaced by the Sussman Automatic service depart ment or similarly qu...

Страница 7: ...ring connections Fully Assembled The electrical outlet shown is for AromaFlo Pump connection only Make no other connections to this outlet Other connections may result in circuit overload CAUTIO N For...

Страница 8: ...Continue until the injector is full of liquid 6 If you have drawn up the injector completely and no liquid is in the injector remove the injector hose from the pressure valve 7 Drain injector Repeat s...

Страница 9: ...____________________________ 0 106 Oz 7 min 30 sec ________________________________________________________ 0 123 Oz 8 min 45 sec ________________________________________________________ Factory Setti...

Страница 10: ...ee page 4 Installation of Pressure Hose IMPORTANT NOTE The valve plate must be level in the pump head Maintenance of Pressure Valve 1 Disconnect power supply 2 Unscrew pressure end nut and remove pres...

Страница 11: ...if necessary 5 Check filter in container for contamination Rinse filter under clean water 6 Check the pressure hose for kinking or jamming Straighten or replace 7 Check if liquid is freely flowing th...

Страница 12: ...AY IN THE PERFORMANCE OF ITS OBLIGATIONS UNDER THIS WARRANTY DUE TO CAUSES BEYOND ITS CONTROL SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS AND OR DO NOT ALLOW THE EXCLUSI...

Отзывы: