CHAPTER 2
MODULAR SERVO
Reference Manual
Description of the Toolbox Functions
33-008-2M5
2-43
SetPW
Purpose:
Set the parameters of the internal excitation.
Synopsis
: es_call( 'SetPW', Par )
Description:
The function sets the parameters of the internal signal source. The
internal signal source is used as:
•
a source of control value for the DC drive in the case of open-loop
control mode (algorithm number 1),
•
a source of reference value for the position in the case of all closed-
loop control algorithms.
The following periodical functions can be selected: constant, square,
triangle, sinusoidal or random.
The elements of the Par argument have the following meaning:
Par( 1 ) = 0: constant value. In this case (Figure 2-1):
Par( 2 ) is the level of the signal,
Par(2)
+1
-1
0
time [s]
Level
Figure 2-1: Constant excitation.