ELECTRICAL CONNECTION AND
GROUNDING INSTRUCTIONS
Electrical Supply Wiring
DANGER:
Improper or faulty hookup of electrical components in the
display case can result in severe injury or death.
THIS CASE MUST BE GROUNDED
Permanent Connection (Standard)
-Only a licensed electrician must perform all case electrical connections.
-All electrical wiring hookups must be done in accordance with all applicable local, regional, or national
electrical standards.
-A separate circuit for each display case is required to prevent other appliances on the same circuit from
overloading the circuit and causing malfunction.
-The electrical service must be grounded upon installation.
-See the electrical data plate located at the rear of the case for circuit load and wire current capacity.
-Standard Base Electrical Connection: The electrical connection box is accessible from the rear of the case.
Power Supply Wiring can be routed through the floor of the base frame or through the access hole in the rear of
the unit. Remove electrical box cover to access electrical connections.
POWER IN BOX
POWER IN ACCESS HOLE
POWER IN BOX
POWER IN ACCESS HOLE
PRIOR TO 01/01/2020
AFTER 01/01/2020
BACK VIEW OF CASE