LEVELING CASE
The drop-
in cases are equipped with adjustable leg levelers with 2” adjustment for leveling the case
with the counter. Blocking may need to be added under the leg levelers for support.
DUCTING CONDENSER AIR INTAKE
Ducting is
REQUIRED
on the inside of the cabinet between the inner front wall of the cabinet and the
base front panels as shown in the diagram above. This is needed to prevent warm condenser air from
recirculating thru the condenser coil. If this is not done it will affect case temperature performance,
shorten the life of the compressor and void the compressor warranty.
DUCT WORK REQUIRED
BETWEEN CONDENSER COIL
AND CABINET TO BLOCK
WARM AIR RECIRCULATION
BLOCKING FOR
ADJUSTABLE LEG
LEVELERS
25.81
OPENING IN CABINET
FRONT MUST BE LARGE
ENOUGH TO PULL OUT
CONDENSING UNIT FOR
SERVICING
COUNTER
FRONT
CONDENSER
COIL
COUNTER
TRIM
Refrigerated Self-Serve Merchandiser (High Profile)