REFRIGERATION AND ELECTRICAL DATA
AFTER 01/01/2020
Model
RSSM360SC-6
RSSM360R-6
RSSD360SC-6
RSSD360R-6
RSSM378SC-6
RSSM378R-6
RSSD378SC-6
RSSD378-R
ELECTRICAL
Power Supply, Volts
208-240Volts
208-240Volts
Frequency
60 Hertz
60 Hertz
Phase
1 Phase
1 Phase
Number of Wires
2 + ground
2 + ground
AMPS VOLTS
AMPS VOLTS
Compressor
RLA
4.3
208-240
---- ----
LRA
31.0
208-240 ---- ----
Condenser Fan Motor
0.6
208-240
---- ----
Evaporator Fan Motor
0.4
208-240 0.4 208-240
Lights
1.0
208-240 1.0 208-240
(Includes Optional Shelf Lights)
Condensate Pan Heater
5.0
208-240 ---- ----
Condensate Pump 0.5 208-24 0.5 208-240
Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and Minimum Circuit Ampacity.
REFRIGERATION
Self-Contained Models
After 01/01/2020 Refrigeration R449a Charge Self-Contained
3 Pounds
The self-contained models are shipped from the factory with a completely operational R449a
refrigeration system and require no modifications or adjustments upon installation. Case must be
installed as per the installation section of this manual to provide proper condensing air cooling.
Self-Contained Refrigeration Operation
The unit temperature is controlled by the Electronic control and timers outlined in the control section
of this manual.
Note: The condenser fan runs continuously.
Remote Models
Refrigerant & BTU Requirements
Refrigerant R404A Before 01/01/18
5400
BTU’S @20°F Evap/90° Ambient
Refrigerant R449a After 01/01/18
5400
BTU’S @20°F Evap/90° Ambient
Refrigerated Self-Serve Merchandiser (High Profile)
Page 31