-16-

LEVEL 5 Load Management

thresholds. Three voltage thresholds are
programmable as follows:

High  Idle  Control Voltage Thresh-

old.

Load Shedding Voltage Threshold.

Low Battery Voltage Alarm Voltage

Threshold.

To  reconfigure  the  voltage  thresholds
when Voltage Threshold is selected, go
to Level 5 - Voltage Threshold, page 18.

High Idle Control
Enable

Press key 15 “High Idle Control Enable”
to  enable/disable  the  High  Idle  relay
output (+12VDC @ 2A max.). The High
Idle output operates in conjunction with
the PARK input. If the vehicle is shifted
out  of  PARK,  the  High  Idle  relay  will
NOT turn on. The key 15 LED is on when
High Idle control is enabled and off when
High Idle control is disabled. The High
Idle  control  and  Common  Microphone
control are mutually exclusive.

Common  Microphone
Control Enable

Press key 7 "Common Microphone Con-
trol Enable" to enable/disable the com-
mon microphone relay output (+12VDC
@ 2A max.). A common microphone mod-
ule  eliminates  the  need  for  two  micro-
phones. The key 7 LED is on when Com-
mon Microphone control is enabled and

Level 5 - Load Management is where you
decide  which  relays  should  shed  (turn
off),  the  shedding  sequence,  what  volt-
age  should  start  shedding,  enabling  of
automatic high idle control, and enabling
of the low voltage alarm.

SAVE

Save LEVEL 5 - Load Management  set-
tings and return to MAIN MENU page
6.

Load Shed Sequence

Press  key  10 “Load  Shed  Sequence”  to
reconfigure how the load manager man-
ages relays. It can be configured so that
relay outputs are not managed. Relays
then opreate in a normal on/off control
mode.

To reconfigure the load manager when
Load  Shed  Sequence  is  selected,  go  to
Level 5 - Load Shed Sequence, page 17.

Voltage Threshold

Press  key  11  “Voltage  Threshold”  to
reconfigure  the  load  manager  voltage

off when Common Microphone control is
disabled.

The  Common  Microphone  control  and
High Idle control are mutually exclusive.

Low Voltage Alarm
Enable

Press  key  16  “Low  Voltage  Alarm  En-
able” to enable/disable the Low Volatge
Alarm. The Low Voltage Alarm turns on
if the unit senses that the battery volt-
age  is  below  the  low  voltage  threshold
for 30 seconds or more.  The key 16 LED
is  on  when  the  Low  Voltage  Alarm  is
enabled  and  off  when  the  Low Voltage
Alarm is disabled.

Higher  Voltage  Settings
Enable

To  enable  the  higher  load  magager
threshold voltage settings (13.8V, 12.8V,
and 11.8V), press key 12. This setting in
conjunction  with  High  Idle  control  en-
able is intended for fire application use.

Lower  Voltage  Settings
Enable

To  enable  the  lower  load  manager
threshold voltage settings (12.8V, 11.8V,
and 11.0V), press key 4.

SmartSystem-LMS

SAVE

9

10

11

12

13

14

15

16

4

5

6

7

8

20

19

17

18

High Idle

Control

Enable

Higher

Voltage

Settings

Enable

Common

Microphone

Control

Enable

Lower

Voltage

Settings

Enable

Low

Voltage

Alarm

Enable

Voltage

Threshold

Load

Shed

Sequence

290A3886C

OFF

1

2

3

Always leave the
Slide Switch OFF
while
reconfiguring.

Содержание SmartSystem SS2000-LMS

Страница 1: ...ON AND CONFIGURATION INSTRUCTIONS Model SS2000LMS SmartSystem Load Management System LOAD MANAGER WITH ELECTRONIC SIREN LIGHT CONTROL SYSTEM AND SignalMaster DIRECTIONAL LIGHT with Slide Switch Contro...

Страница 2: ...h examination reveals a defect in material and or workmanship This warranty does not cover travel expenses the cost of specialized equipment for gaining access to the product or labor charges for remo...

Страница 3: ...siren A H Will produceAir Horn tone any time it is pressed LRC O SignalMaster Arrow Step through Left Right Center Out Off WARN SignalMaster Warn Step through Warn 1 2 3 4 Off FAST SignalMaster Arrows...

Страница 4: ...ss You will find that filling out the worksheet will help greatly reduce the time needed to configure your system to meet your requirements Once you have determined how your system should operate use...

Страница 5: ...lay Push on Push off Momentary 8 Second Timer Security Timer LEVEL 3 Power Up Select which keys should automatically activate when first powered up LEVEL 4 Horn Ring Select Horn Ring Transfer Function...

Страница 6: ...4...

Страница 7: ...less effective at warning others Maximum sound output will be severely re duced if any objects are in front of the speaker If your installation has obstructions in front of the speaker drive even more...

Страница 8: ...end the configuration session and put the system into op eration mode LEVEL 1 Pressing LEVEL 1 Key 10 will enter LEVEL 1 Keyboard If LEVEL 1 is selected go to page 7 LEVEL 1 Keyboard LEVEL 2 Pressing...

Страница 9: ...e the siren tone will be produced Which slide switch will turn on the sirens is optional and will be dis cussed in Level 2 Slide Switch Function on page 10 Default Configuration If key 15 is on then t...

Страница 10: ...If Slide Switches is selected go to page 9 Level 2 Slide Switches Aux Relay Keys Pressing Aux Relay Keys Key 14 will enter LEVEL 2 Aux Relay Keys If Aux Relay Keys is selected go to page 11 Level 2 Au...

Страница 11: ...figure Slide Switch 1 Slide 2 Press Slide 2 to reconfigure how Slide Switch position 2 functions If Slide 2 is selected go to Level 2 Slide Switch Function page 10 to reconfigure Slide Switch 2 Slide...

Страница 12: ...rn Ring Transfer can be con figured to automatically turn on with the Slide Switches To do so turn on Key 15 Horn Ring Trans fer Siren Enable If sirens are configured to be depen dent on the slide swi...

Страница 13: ...Aux Relay C Press Aux Relay C to reconfigure how Aux Relay C key 6 functions IfAux Relay C is selected go to Level 2 Aux Relays Function page 12 to reconfigure Aux Relay C Aux Relay D Press Aux Relay...

Страница 14: ...nt the Aux Relay you are con figuring to automatically turn itself off after 8 seconds Security Timer Select Security Timer Key 15 if you want the Aux Relay you are con figuring to require security op...

Страница 15: ...eys page 8 RAD WAIL YELP MAN A H Turn on the key to enable one of the above tones key Turn off the key to disable one of the above tones key H L or PRIORITY Key 14 can be configured to activate either...

Страница 16: ...utomatically when the system is powered up Remember only one siren or the RAD key can be selected at a time If no sirens or RAD is selected the system will power up in stand by Note If the sirens are...

Страница 17: ...d and you press the horn If the tone cannot transfer to a more urgent tone the Air Horn will mo mentarily sound Activate key 13 if you want YELP to be this tone Activate key 14 if you want PRIORITY No...

Страница 18: ...equence Press key 10 Load Shed Sequence to reconfigure how the load manager man ages relays It can be configured so that relay outputs are not managed Relays then opreate in a normal on off control mo...

Страница 19: ...onds or more If the High Idle Control is enabled High Idle will activate to remedy the low battery condition before load shedding begins Previously shed loads are NOT restored if the bat tery voltage...

Страница 20: ...adjustable voltage threshold range is 11 15 volts The flow chart on page 19 illustrates how the load manager works in conjunction with volt age thresholds Press key 9 to save after all voltage thresh...

Страница 21: ...n EXIT C1 C2 C3 Shed load according to the programmed sequence Volts 13 8V for 30 sec Volts 12 8V for 30 sec Volts 12 8V for 30 sec Turn High Idle Off NOTE 11 8V 12 8V AND 13 8V CAN BE PROGRAMMED TO B...

Страница 22: ...Siren Enable Circle the tones switches to be enabled RAD WAIL YELP H L or PRIORITY MAN A H Level 1 Sirens independent of slide switch Yes No Function Indicator Sound Yes No SignalMaster Type 6 Lamp 8...

Страница 23: ...mperes max Relay 2 20 amperes max Relay 3 40 amperes max Relay A 10 amperes max Relay B 10 amperes max Relay C 10 amperes max Relay D 10 amperes max Relay E 10 amperes max Is Horn Ring Transfer used Y...

Страница 24: ...Printed in U S A 255333E REV E 903...

Отзывы: