Mounting the Light

Model QL73LEDSCENE 

Federal Signal

 www.fedsig.com

Mounting the Light

AIRBAG DEPLOYMENT: Do not install equipment or route wiring in 

the deployment path of an airbag. Failure to observe this warning 

will reduce the effectiveness of the airbag or potentially dislodge 

the equipment, causing serious injury or death.

Before proceeding, determine the approximate location of the light 

assembly and plan all cable/wire routing. 

IMPORTANT:

 For maximum coverage and effectiveness, the 

light assembly must be mounted in a horizontal orientation. (See 

Figure 1 on page 9.)
To mount the scene light:

1. 

Position the light assembly the mounting surface. Ensure that 

the light is level side to side. 

2. 

Using the dimensions provided in Figure 2 on page 10, 

scribe the four mounting hole locations and a wiring routing 

hole location on the mounting surface.

DRILLING PRECAUTIONS: When drilling holes, check the area 

you are drilling into to ensure that you do not damage vehicle 

components while drilling. All drilled holes should be de-burred, 

and all sharp edges should be smoothed. All wire routings going 

through drilled holes should be protected by a grommet or 

convolute/split loom tubing.

3. 

Drill four 1/4­inch mounting holes and a wire routing hole 1­inch 

at the scribed locations. 

4. 

Install the four supplied screw grommets into the four 1/4­inch 

mounting holes.

5. 

Complete the electrical connections as described in “Wiring the 

Light” on page 11.

Содержание QuadraFlare QL73LEDSCENE

Страница 1: ...25500209 Rev B1 0320 Printed in U S A Copyright 2015 2020 Federal Signal Corporation Installation and Maintenance Instructions QuadraFlare Model QL73LEDSCENE 7x3 LED Scene Light...

Страница 2: ...This limited warranty is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness for a particular...

Страница 3: ...iring the Light 11 Cleaning the Lenses 12 Safety Message to Operators 13 Ordering Replacement Parts 14 Getting Technical Support and Service 15 Getting Repair Service 15 Figures Figure 1 Exploded view...

Страница 4: ...be recalibrated for proper airbag deployment When drilling into a vehicle structure ensure that both sides of the surface are clear of anything that could be damaged Locate the light control so the VE...

Страница 5: ...in Solaris LED technology the scene light focuses lighting around the perimeter of the vehicle without using angled bezels Features Surface mounted LED scene light Solaris LED Technology provides foc...

Страница 6: ...ntact Customer Support at 1 800 264 3578 7 a m to 5 p m Monday through Friday CT Table 1 Kit contents Qty Description Part Number 4 6x1 1 2 inch Stainless Steel Screw 7011205 24 4 Screw Grommet 706507...

Страница 7: ...assembly the mounting surface Ensure that the light is level side to side 2 Using the dimensions provided in Figure 2 on page 10 scribe the four mounting hole locations and a wiring routing hole loca...

Страница 8: ...gasket and the light as sembly with the screw grommets and secure it with the provided 8 by 1 1 2 inch stainless steel screws Be sure to have the lens mounted to the assembly with the top side of the...

Страница 9: ...8 15 3 290A7964 Table 2 Legend for Figure 1 No Description No Description 1 Mounting Screw 8 X 1 1 2 in S S 9 Vent 2 Reflector 10 Grommet 3 Control PC Board Assy 11 Wire Harness 4 LED PC Board Assy 1...

Страница 10: ...ght Model QL73LEDSCENE Federal Signal www fedsig com Figure 2 Dimensions of mounting holes on vehicle 290A7965 6 56 2X 2 38 2X 1 19 2X 0 25 4 Places 1 00 3 28 2X Figure 3 Interior of scene light base...

Страница 11: ...18 AWG minimum wire Ensure that all wires are properly connected and insulated ap propriately LIGHT HAZARD This product contains high intensity LED devices To prevent eye damage DO NOT stare into the...

Страница 12: ...ATE LENSES To extend the life of this device periodic cleaning is necessary Clean the lens with a mild non abrasive neutral pH cleaning agent and a soft clean cloth Rinse the device thoroughly to ensu...

Страница 13: ...People may not see or heed your warn ing signal You must recognize this fact and continue to drive cautiously Situations may occur that obstruct your warning signal when natural or manmade objects ar...

Страница 14: ...distributor or Customer Support Federal Signal Corporation Phone 1 800 264 3578 1 708 534 3400 Monday Friday 7 00 a m to 5 00 p m CST http www fedsig com Table 3 Replacement parts Description Part Nu...

Страница 15: ...nal factory provides technical assistance with any problems that cannot be handled locally Any units returned to returned to Federal Signal for service inspection or repair must be accompanied by a Re...

Страница 16: ...ral Signal Drive University Park Illinois 60484 www fedsig com Customer Support Police Fire EMS 800 264 3578 1 708 534 3400 Work Truck 800 824 0254 1 708 534 3400 Technical Support 800 433 9132 1 708...

Отзывы: