![Federal Signal Corporation Informer100 Speaker Скачать руководство пользователя страница 13](http://html2.mh-extra.com/html/federal-signal-corporation/informer100-speaker/informer100-speaker_description-specifications-and-installation-manual_3837623013.webp)
13
Installation
Description, Specifications, and Installation Manual
Federal Signal
www.fedsig.com
JP5 Initiation inputs 1 and 2 – ISO Ground/Input 1
3 and 4 – ISO Ground/Input 2
5 and 6 – ISO Ground/Input 3
7 and 8 – ISO Ground/Input 4
NOTE
: Each input is activated by shorting the two pins associated
with the input.
JP6, JP7, JP8, and
JP9
AC or DC Power
Distribution
1 – L1/Hot/(+) 24 Vdc
2 – L2/Neutral/(-) 24 Vdc Gnd
3 – Earth Ground
NOTE
: JP6, JP7, JP8 and JP9 are physically connected to provide
a distribution of AC or DC power. The combined load of all power
should not exceed 8 amperes AC/DC, 25 A max inrush
JP10
Reserved for factory testing
JP11
Short to restore factory default settings
JP12
Reserved for factory testing
Table 6 Environmental and Physical
Operating temp range
-40˚F to 150˚F (-40°C to +66°C) at 20% duty cycle.
Continuous duty UL rating: -40˚F to 104˚F / (-40˚C to 40˚C).
Humidity range
0-95%, non-condensing
Size
(Height x Width x Length)
7 x 9 x 10 inches (17.8 x 22.9 x 25.4 cm)
Weight
I-IP100DC
I-IP100AC
16.2 lb (7.35 kg)
19.2 lb (8.71 kg)
Installation
Read and adhere to all safety warnings in this manual before installing the
Informer100 Speaker.
ELECTROCUTION HAZARD: Electrocution or severe personal injury can occur
when making electrical connections, drilling holes, or lifting equipment. Therefore,
experienced electricians, per national and local electrical codes, acting under the
direction of the installation crew safety foreman, should perform the installation.
Determine a Suitable Location
The Informer100 can be mounted on any relatively flat surface with the supplied mounting
brackets. The mounting surface must be capable of supporting the weight of the speaker.