12
Specifications
Informer100 Speaker Series C (Models I-IP100AC and I-IP100DC)
Federal Signal www.fedsig.com
Audio Storage
Warning siren audio, seven factory installed tones: Wail,
Steady, Alternate Wail, Alternate Steady, Pulsed Wail,
Pulsed Steady, Auxiliary Chime
Prerecorded files—up to 4,000 voice or tone messages
with 17 hours of total recording time
Audio Data
8 bit 8 kHz mono wave (G7.11 μ-law)
Audio Frequency response
300 Hz to 3000 Hz, +1 to -3 dB per octave
Maximum Audio Output
100 watts, 120 dBa tones/114.5 dBa for voice at 10 feet
The following indicators are for troubleshooting purposes only. These indicators are not
visible when the unit is closed.
Table 4 Visual Indications (Located on internal control board.)
POWER
Green LED turns on when power is connected. (D5)
ISOLATED POWER Green LED turns on when Isolated power for inputs and relay
outputs is functioning. (D6)
CPU
Flashing RED LED indicates the CPU is running its program. (D18)
NETWORK
Green LED turns on when unit has made a connection to the
network. (D27)
LISTEN
Red LED turns on when Commander
®
is listening. Unit is sending
audio to Commander. (D25)
TALK
Green LED turns on when Commander is talking. Unit is playing
audio being sent. (D26)
AMPOUTPUT
VOLTAGE
Green LED turns on when amplifier is active. Brightness indicates
level of amplifier output. (D2)
AMPLIFIER
OUTPUT
CURRENT
Green LED turns on when amplifier is active. Brightness indicates
level of amplifier output. (D8)
ACTIVATION
INPUT #1
Red LED turns on when Activation input #1 is being activated. (D13)
ACTIVATION
INPUT #2
Red LED turns on when Activation input #2 is being activated. (D15)
ACTIVATION
INPUT #3
Red LED turns on when Activation input #3 is being activated. (D19)
ACTIVATION
INPUT #4
Red LED turns on when Activation input #4 is being activated. (D20)
Table 5 Connectors and Jacks (Control board connectors)
JP2
Serial Port for factory approved programming or for message board
display
JP3 Pin Jack
Reserved for factory testing
JP4 Relay Outputs
1 and 2 mechanical relay Normally Open
3 – DC solid-state relay, (+) DC power
4 – DC solid-state relay, Switched (+) DC power to strobe or light
5 – AC solid-state relay
6 – AC solid-state relay
NOTE
: Mechanical relay output is programmed as Relay 1. Solid-
state relays are programmed as Relay 2.