background image

9

Federal Signal

 signaling.fedsig.com

Ordering Replacement Parts

Consult the product datasheet online for an updated list 

of replacement parts. If the product requires a part that 

is not available for purchase, your unit must be repaired 

or replaced. The product’s dome should be regularly 

inspected for scratches or chips and, if damaged, it must 

be replaced. A strap wrench (6" capacity) may be used to 

aid in the dome removal. 

 Table 2  

Replacement parts

Description

Part Number

Lens Guard

K859500821-02

Lens, Amber

K859500815

Lens, Blue

K859500815-01

Lens, Clear

K859500815-02

Lens, Green

K859500815-03

Lens, Red

K859500815-04

Lens, Magenta

K859500815-05

Lens, Yellow

K859500815-06

Lens Guard (High Profile Lens Version) K859500821-01
Lens, Amber (High Profile Lens 

Version)

K859500814

Lens, Blue (High Profile)

K859500814-01

Lens, Clear (High Profile)

K859500814-02

Lens, Green (High Profile)

K859500814-03

Lens, Red (High Profile)

K859500814-04

Lens, Magenta (High Profile)

K859500814-05

Lens, Yellow (High Profile)

K859500814-06

DC LED (24VDC) Internal Sub-Assembly Kits (Includes 

PCBA, bracket, LED light head and mounting screw)
Description

Part Number

LED/PCB DC Sub-Assembly, Amber

K859501400-A

LED/PCB DC Sub-Assembly, Blue

K859501400-B

LED/PCB DC Sub-Assembly, White

K859501400-W

LED/PCB DC Sub-Assembly, Green

K859501400-G

LED/PCB DC Sub-Assembly, Magenta K859501400-W
LED/PCB DC Sub-Assembly, Red

K859501400-R

LED/PCB DC Sub-Assembly, Yellow

K859501400-W

AC LED (120-240VAC) Internal Sub-Assembly Kit 

Includes PCBAs, bracket, LED light head and mounting 

screw)
Description

Part Number

LED/PCB AC Sub-Assembly, Amber

K859501401-A

LED/PCB AC Sub-Assembly, Blue

K859501401-B

LED/PCB AC Sub-Assembly, White

K859501401-W

LED/PCB AC Sub-Assembly, Green

K859501401-G

LED/PCB AC Sub-Assembly, Magenta K859501401-W
LED/PCB AC Sub-Assembly, Red

K859501401-R

LED/PCB AC Sub-Assembly, Yellow

K859501401-W

 Table 3  Accessories

Description

Part Number

Indicator Ring/Legend Kit, Black

G-KIT-RP-BK

Indicator Ring/Legend Kit, Blue

G-KIT-RP-B

Indicator Ring/Legend Kit, Green

G-KIT-RP-G

Indicator Ring/Legend Kit, Magenta

G-KIT-RP-M

Indicator Ring/Legend Kit, Red

G-KIT-RP-R

Indicator Ring/Legend Kit, Yellow

G-KIT-RP-Y

E-Box Endcap with M20 Opening

K859500805-02

E-Box Endcap with M25 Opening

K859500805-01

E-Box Cover Assembly (Includes 

two terminal blocks, mounting plate, 

retention hardware)

K859501414

In-Line E-Box Coupler Kit

G-KIT-EC180

90-Degree E-Box Coupler Kit

G-KIT-EC90

Extension Box Spacer Kit

G-KIT-EXTB

Single Trunnion Kit

G-KIT-ST

Dual Trunnion Kit

G-KIT-DT

Adapter, M20 Male to 1/2" Female NPT K231246A
Adapter, M20 Male to 3/4" Female NPT K231247

Содержание G-LED Series

Страница 1: ...erts have the potential to store charge when they are not plugged Consideration should be taken to prevent these from becoming a sparking hazard Model G LED LED Beacon For Use in Hazardous Locations T...

Страница 2: ...and use in provisions of Articles 505 and 506 of NFPA 70 NEC These models use protections Class I Zone 1 AEx db op is IIC T4 Gb or AEx db eb op is IIC T4 Gb Zone 21 AEx op is tb IIIC T135 C Db IP66 Ta...

Страница 3: ...le for the surface to which the device will be mounted Figure 2 Front view of Ex d beacon 105 9 mm 4 17 in 105 9 mm 4 17 in 105 9 mm 5 27 in 4X COUNTER BORED HOLES TO FIT M8 SOCKET HEAD CAP SCREWS Fig...

Страница 4: ...he M25 entry on the end of the increased safety box models See Table 3 on page 26 for choosing the correct cable entry devices for Equipment in Potentially Explosive Atmospheres Because of space limit...

Страница 5: ...L1 b Connect the neutral common power source wire to the terminal block screw marked L2 c Connect the ground wire to the terminal block clamp marked GND 5 Insert the PCB into the enclosure and fully t...

Страница 6: ...e wire to the terminal block pole marked L1 See Figure 10 Figure 10 Connections for DC or AC Ex de beacons Aud L1 L2 L3 Alt Aud Aud L1 L2 L3 Alt Aud A A b Connect the negative power source wire to the...

Страница 7: ...before operating this system If you acquired a significant quantity of units then it is recommended that spares also be made available Any maintenance to the beacon system must be done with power turn...

Страница 8: ...cover will not unscrew back out the set screw a few additional turns 4 Loosen the captive Phillips screw retaining the printed circuit board PCB and slide the PCB out of the housing 5 Unplug the J1 co...

Страница 9: ...01400 B LED PCB DC Sub Assembly White K859501400 W LED PCB DC Sub Assembly Green K859501400 G LED PCB DC Sub Assembly Magenta K859501400 W LED PCB DC Sub Assembly Red K859501400 R LED PCB DC Sub Assem...

Страница 10: ...ain the ingress protection of the flameproof beacon enclosure we recommend the cable entry device be IP66 certified G LED XXX E X Ex db surface mount Gas For the flameproof beacon enclosure cable entr...

Отзывы: