Installation and Maintenance Manual
LP800 Solaris Beacon
Federal Signal
www.fedsig.com
Product Specifications
Table 1
Specifications
Input Voltage
10 Vdc to 30 Vdc
Nominal
12.8 Vdc or 25.6 Vdc
Input Current, Amber
(nominal)
2 A at 12.8 Vdc pulsed, 0.8 avg.
1 A at 25.6 Vdc pulsed, 0.4 avg.
Dimensions
Height
4.67 inches (118.5 mm)
Diameter
6.45 inches (164 mm)
Weight
(permanent mount/
pipe mount)
1.54 lb (0.7 kg)
Approvals
SAE J1318, J845 Class 1, J845 Class 2
Operating temperature
-20°C to 50°C (-4°F to 122°F)
Permanently Mounting the Beacon
LIGHT HAZARD: To be an effective warning device, an emergency
warning system produces bright light that can be hazardous to your
eyesight when viewed at a close range. Do not stare directly into
this lighting product at a close range, or permanent damage to your
eyesight may occur.
To permanently mount the beacon:
1.
Using the dimensions shown in Figure 7 on page 19, scribe
the locations of the three mounting holes and hole for the
cable.
DRILLING PRECAUTIONS: When drilling holes, check the area
you are drilling into to ensure that you do not damage vehicle
components while drilling. All drilled holes should be deburred,
and all sharp edges should be smoothed. All wire routings going
through drilled holes should be protected by a grommet or
convolute/split loom tubing.
2.
Drill three 9/32-inch (7 mm) holes at the scribed mounting hole
locations. Drill one 25/64-inch (10 mm) hole at the scribed hole
for the cable.