Limited Warranty

 

 

The  Alerting  and  Notification  Systems  Division  of 

Federal  Signal  Corporation 

(Federal) 

warrants  each  new  product  to  be  free  from  defects  in  material  and 

workmanship,  under  normal  use  and  service,  for  a  period  of  two  years  on  parts 
replacement and factory-performed labor (one year for Informer, and Federal software 
products) from the date of delivery to the first user-purchaser.  Federal warrants every 
2001, Eclipse and 508 Siren (Top of pole only) to be free from defects in material, per 
our standard warranty, under normal use and service for a period of five years on parts 
replacement. 
 
During  this  warranty  period,  the  obligation  of  Federal  is  limited  to  repairing  or 
replacing,  as  Federal  may  elect,  any  part  or  parts  of  such  product  which  after 
examination  by  Federal,  are  determined  to  be  defective  in  material  and/or 
workmanship. 
 
Federal will provide warranty for any unit which is delivered, transported prepaid, to 
the  Federal  factory  or  designated  authorized  warranty  service center  for  examination 
and such examination reveals a defect in material and/or workmanship. 
 
This  warranty  does  not  cover  travel  expenses,  the  cost  of  specialized  equipment  for 
gaining access to the product, or labor changes for removal and re-installation of the 
product.  The  Federal  Signal  Corporation  warranty  shall  not  apply  to  components  or 
accessories  that  have  a  separate  warranty  by  the  original  manufacturer,  such  as,  but 
not limited to batteries. 
 
Federal  will  provide  on-site  warranty  service  during  the  first  60-days  after  the 
completion  of  the  installation,  when  Federal  has  provided  a  turn-key  installation 
including optimization and/or commissioning services. 
 
This warranty does not extend to any unit which has been subjected to abuse, misuse, 
improper  installation  or  which  has  been  inadequately  maintained,  nor  to  units  which 
have  problems  related  to  service  or  modification  at  any  facility  other  than  Federal 
factory  or  authorized  warranty  service  centers.    Moreover,  Federal  shall  have  no 
liability  with  respect  to  defects  arising  in  Products  through  any  cause  other  than 
ordinary  use  (such  as,  for  example,  accident,  fire,  lightning,  water  damage,  or  other 
remaining acts of God). 

 

THERE  ARE  NO  OTHER  WARRANTIES,  EXPRESSED  OR  IMPLIED,  INCLUDING  BUT 
NOT  LIMITED  TO,  ANY  IMPLIED  WARRANTIES  OF  MERCHANTABILITY  OR 
FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL FEDERAL BE LIABLE 
FOR  ANY  LOSS  OF  PROFITS  OR  ANY  INDIRECT  OR  CONSEQUENTIAL  DAMAGES 
ARISING OUT OF ANY SUCH DEFECT IN MATERIAL WORKMANSHIP. 

 

 

2645 Federal Signal Drive, University Park, IL 60484 

Phone: 800.524.3021   Fax: 708.534.4865    

www.alertnotification.com 

Содержание 2-240

Страница 1: ...2 120 2 240 FEDERAL SIGNAL CORPORATION S MODELS Outdoor Warning Sirens INSTALLATION OPERATION SERVICE MANUAL Copyright 2006 Federal Signal Corporation 255154R 07 13...

Страница 2: ...ges to devices and specifications detailed in the manual at any time in order to improve reliability function or design The information in this book has been carefully checked and is believed to be ac...

Страница 3: ...when an emergency condition exists they cannot provide the intended audible warning It is imperative that knowledgeable people who are provided with the necessary information are available at all tim...

Страница 4: ...test the siren system to confirm that it is operating properly Test the system regularly to confirm that it will be operational in an emergency If future service personnel do not have these warnings a...

Страница 5: ...labor changes for removal and re installation of the product The Federal Signal Corporation warranty shall not apply to components or accessories that have a separate warranty by the original manufac...

Страница 6: ...Read and understand the information contained in this manual before attempting to install or service the siren Pay careful attention to the following notices located on the equipment NOTICES EXTERNAL...

Страница 7: ...Description 3 SECTION II SPECIFICATIONS 2 1 Model 2 4 SECTION III INSTALLATION 3 1 Siren Location 5 3 2 Physical Installation 6 3 3 Electrical Connections 11 3 4 Preoperation Checks 12 SECTION IV CIR...

Страница 8: ...n models enables them to produce a high sound level while making moderate demands on the power source 1 3 SIREN DESCRIPTION The Model 2 Siren Figure 1 1 is a 102dB single tone siren The Model 2 siren...

Страница 9: ...pplications or any other process that can be controlled via relay contacts The microprocessor based controller contains the following features Synthesized Radio Receiver Low Band High Band or UHF 3 se...

Страница 10: ...he steady signal is frequently used as a Civil Defense Alert signal The wailing signal is often used as a Civil Defense Attack However the signal can be used for any desired indication These signals a...

Страница 11: ...r 18 46 cm Height 25 5 65 cm Shipping Weight 85 lb 36 kg Miscellaneous Sound Output 102dBC at 100 ft 30 5m Model 2 Motor Type Single phase ball bearing universal series 120Vac dc or single phase ball...

Страница 12: ...height of the siren Optimum sound propagation conditions exist when there are no obstructions in the sound path the terrain is flat and the air is calm Under these conditions each time the distance f...

Страница 13: ...e the ground If the installation is less than 35 feet above the ground the sound intensity at close range may increase but the effective range of the siren may be reduced Conversely if the siren is lo...

Страница 14: ...h leg If necessary install shims between the siren legs and the pole g Wrap a cable or chain capable of bearing at least one ton around the pole siren combination at least three times Wrap the chain o...

Страница 15: ...8 Figure 3 2 Typical Model 2 Pole Mounted Installation...

Страница 16: ...en It will be reinstalled later d Mount the siren base plate assembly on the mounting surface using lag bolts or nuts and bolts as appropriate Do NOT replace the housing on the siren It will be replac...

Страница 17: ...10 Figure 3 3 Typical Model 2 Platform Mount...

Страница 18: ...knockouts can accommodate 1 2 conduit fittings others can accept 3 4 conduit fittings and still others can accommodate 1 conduit fittings These various sized knockout holes are provided because elect...

Страница 19: ...le mounted installations drive a metal rod or bar at least two feet 61 cm into the ground or as close as practical to the base of the pole For maximum protection use a separate continuous 10AWG or lar...

Страница 20: ...otection for the siren motor As shown in figure 3 4 the motor starter includes an overload relay The relay protects the motor starter and the motor in the event that excess current is drawn The overlo...

Страница 21: ...siren for proper operation at least once a month A daily test at noon curfew or other selected time is preferred This not only enhances the usefulness of the siren but also instills public confidence...

Страница 22: ...ke sure that the cap seats properly However do not tighten the cap excessively or it may break C Model 2 Armature and Field Replacement 1 Armature a Turn off the power to the siren at the disconnect s...

Страница 23: ...ng from the motor housing f Arrange two spacers consisting of 4 x 4 102mm x 102mm lumber or similar material approximately 5 127mm apart on a solid work surface as shown in figure 5 2 g Sharply rap th...

Страница 24: ...e two mounting holes in the body of the field as shown in figure 5 3 Be sure that the four wires are in the position shown in figure 5 3 k Set a length of 3 8 9 5mm steel bar stock approximately 5 127...

Страница 25: ...oad Heater s Replace Motor starter inoperative Faulty motor starter control Replace coil winding Motor starter overload relay Reset relay tripped Faulty overload heater s Replace heater s Open circuit...

Страница 26: ...L01 08 1 12 Rotor L01 21 1 13 Key 8247A057 1 14 Armature 120V 8247B041G 1 AR Armature 240V 8247B039G 15 Locking Ring Field L01 20 1 16 Field 120V 8247B042G 1 AR Field 240V 8247B040G 17 Spring Lockwas...

Страница 27: ...22 Figure 5 6 Model 2 Parts Index...

Страница 28: ...and Springs Power Pole 8217C182 11 2 sets 3 Contacts and Springs Interlock 8217C180 12 1 set 4 Coil 60 Hz 120 240V 8217C180 16 1 5 Overload Heaters K 58 120V 8217C182 20 1 Overload Heaters K 42 240V...

Страница 29: ...24...