- 24 -
Top Section Refrigeration Louver Control
AIR CONTROL
LOUVER ASSEMBLY
AIR CONTROL
ADJUSTMENT
KNOB
AIR CONTROL
ADJUSTMENT KNOB OUT
AIR CONTROL
ADJUSTMENT KNOB IN
LOUVER CLOSED POSITION
LOUVER OPEN POSITION
The top section of this unit can be changed from a refrigerated section to a non-refrigerated section by
opening or closing the louver. Unlock the louver position by loosening the control knob (turn control knob
counter clockwise) and lock the louver position by tightening the control knob (turn control knob
clockwise). Sliding the air control knob out will open the louver making the top section refrigerated and
sliding the air control knob in will close the louver making the top section non-refrigerated (see illustration
above). Even with the louver in the closed position the top section will be colder then ambient. If a
refrigerated section is required for potentially hazard food the air control louver must be completely open.
A half open louver will not allow sufficient air flow to top section. The air control louver assembly can be
placed in the case in either direction. The air control knob can either be facing the inside or the outside of
the case. The side that the air control knob is facing will not affect case operation.
NOTICE:
If a top refrigerated section is required for potentially hazard food the
air control louver must be completely open. A half open louver will not
allow sufficient air flow to top section.
Placing Product into Case
-
Do not exceed 75 pounds of weight per shelf. Heavy product should be distributed evenly across
the entire shelving area.
- Determine desired shelving location and angle before placing product in case. Product must be
removed to readjust shelf location and angle.
-
Allow a minimum of 2” between top of product and bottom of shelf as shown in diagram below.
-
Do not overhang the front or rear of shelves with product. Improper clearance in front and rear of
shelf will block the refrigerated airflow and will cause product loss.
-
Do not block the slots along the front and rear air discharge areas. Covering these slots will block
the refrigerated airflow and could cause product loss.
-
The display deck is removable for cleaning and can become dislodged in shipment. To ensure
proper airflow and performance of the case, make sure that the display deck is pushed
completely down into evaporation tub.
-
Allow refrigerated models to run for at least two hours before placing pre-chilled product into unit.
NOTICE:
CASE MUST BE STOCKED WITH PRE-CHILLED PRODUCT ONLY.
NOTICE:
This refrigerated display case is designed to operate
in a maximum environment of 80 DEG. F and 55% relative
humidity. Exceeding these limits will cause poor case
performance and sweating of glass panels.