1.2      FDC Orion-M  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT IS THE ORION-M? 

The  Orion-M  provides  a  rich  set  of  tools  for  control  interaction  and  data  analysis.    Views  include  system 
overviews,  trends,  alarms,  profiles  as  well  as  historical  data,  alarm  history  and  audit  trail  views.    The  menu 
driven  interface  eliminates  screen  ‘clutter’  by  providing  an  easy  to  use  ‘Windows’  interface  for  interaction 
between the user and the Orion-M system.  
 
The Orion-M can store more than one  year  of data  on its  internal compact flash card.  Data  logging can be 
enabled  manually  or  automatically  during  automatic  profile  run.    Data  backup  is  provided  with  the  ‘USB  I-
Stick’ for plug and play transfer of files to any PC running Microsoft Windows XP operating systems. 
 
The  Orion-M  security  module  provides  full  system  security  with  three  levels  of  access.    Each  of  the  three 
access  levels  allow  for  independent  user  rights.    Up  to  30  users  can  be  entered  into  the  system  while  the 
audit trail tracks all operator actions and records them.  
 
 

The Orion-M control system includes the following interface features: 

 

 

Overview screen that displays all “runtime” information. 

 

Profile run and monitor views. 

 

Profile entry, open, save and download interface screens. 

 

Current alarm and alarm history views (alarm history for up to 1 year). 

 

Real time trends (with adjustable X,Y limits) for all inputs. 

 

System and application setup (control loops, monitors, inputs/outputs, alarms, etc.).   

 

Data logging interface screens include log point selection and historical viewing. 

 

‘Plug and Play’ memory stick functionality for data transfer/backup. 

 

Full USB print capabilities and on-line help screens 

 

Web server for intranet/internet access (view only). 

 

VNC server for intranet/internet access (control/view). 

 

FTP data back-up for automatic data file transfer over intranet/internet. 

 

Integrated email server for alarm notification and file transfer. 

 

NTS clock with daylight savings time insures that the system is up to date. 

 

Full security with audit trail for tracking user actions. 

 

Maintenance counters for output cycles and on times. 

 

Helps screens are available for most screen views; configurable in English, Spanish and French 

 

Voice assisted help in English, Spanish and French (external speakers required – not included). 

 
 

Содержание Orion-M

Страница 1: ...Orion M Honeywell UDC2500 3200 Series Controller System Guide Rev C February 7 2011 Supersedes Rev B March 25 2010 Orion M Honeywell UDC2500 3200 Controller System Guide...

Страница 2: ...ion to verify that your selections are consistent with your application inputs outputs alarms limits etc If the problem persists after checking the above you can get technical assistance by dialing 1...

Страница 3: ...1 1 Communications Wiring 2 1 3 Configuring the Honeywell UDC2500 3200 Controller 3 1 3 1 Assigning the Proper Communications Settings 3 1 3 2 Input Type Assignments 3 2 3 2 1 Input 1 Operation 3 2 3...

Страница 4: ......

Страница 5: ...No other control system on the market provides the flexibility functionality and configurability of the Orion M 1 1 Features The digital inputs of the Orion M can be configured as alarm inputs with a...

Страница 6: ...includes the following interface features Overview screen that displays all runtime information Profile run and monitor views Profile entry open save and download interface screens Current alarm and a...

Страница 7: ...ring to and form the UDC controllers be routed away from all high voltage and or output control wiring This will minimize the chances of electrical transients or spikes in the power control wiring fro...

Страница 8: ...UDC2500 or UDC3200 Product Manual for all other connections including power sensor and control wiring Since no two applications are the same it is up to the system designer to insure that the control...

Страница 9: ...munications link beginning with 1 up to the total number of controllers As control loops are enabled in the Orion M Configurator the Orion M will automatically use the Loop Input as the corresponding...

Страница 10: ...he Orion M Configurator the temperature units in the Orion M must match the UDC controllers for the drybulb wetbulb calculation to be performed correctly If the temperature units do not match the rela...

Страница 11: ...f the loop control is visible to the operator it is recommended that the Monitor Input Offset screen be hidden see Section 3 6 Orion Functions Startup View in the Orion M Configuration Manual or even...

Страница 12: ...M is designed to send the shed timer reset command to the UDC controller to take it out of computer set point control when the set point permission is enabled This allows control via the keypad of the...

Страница 13: ...Orion M APPENDIX FDC Orion M A 1 Appendix...

Страница 14: ...ter delivery to the first purchaser for use There are no expressed or implied Warranties extending beyond the Warranties herein and above set forth Limitations Future Design Controls provides no warra...

Отзывы: