WHAT IS THE ORION-M?   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

        

 

FDC Orion-M 

1.1 

 

1  What is the Orion-M? 

The  Orion-M  is  a  multi-loop  process  control  system  combined  with  an  embedded  SCADA  color  touch 
interface.  The Orion-M provides a configurable control platform for a variety of OEM applications requiring up 
to  15  separate  loops  of  control.    In  addition  to  15  loops  of  control,  the  Orion-M  can  also  provide  up  to  an 
additional 15 inputs for process monitoring, for a total of 30 process inputs. 
 
The system is provided with eight 24Vdc digital inputs, two 24Vdc outputs and 6 relay outputs standard.  The 
Orion-M can be expanded to a total of 16 digital inputs and 32 digital outputs.  The Orion-M also provides the 
capability of accepting analog inputs for remote set point control and analog outputs capable of retransmitting 
system variables (PV, SP or %Out) to other devices such as a chart recorder.  The 0-10Vdc or 4-20mA user 
selectable signals are provided through the addition of optional analog expander cards.  
 
The  Orion-M  complements  its  versatile  hardware  platform  by  providing  a  host  of  standard  features  and 
configuration capabilities, all through its visual, touch interface.  The touch screen interface is an embedded, 
industrial PC with all software included.  No external PC software is required for setup or configuration of the 
Orion-M.  All of the setup and configuration data is saved to the Orion-M’s internal memory.  
 
Individual  process  controllers,  one  for  each  loop  in  the  system,  provide  reliable,  consistent  and  accurate 
control by distributing the process control requirements of the system among multiple processors.  Each loop 
controller  provides  full  auto  tune  functionality  with  high  resolution,  universal  process  inputs.   When  coupled 
with  the  built  in  ramping  profiler  of  the  Orion-M,  it  allows  for  automatic,  timed  control  of  all  processes  and 
outputs  of  the  system.    No  other  control  system  on  the  market  provides  the  flexibility,  functionality  and 
configurability of the Orion-M. 
 
 

1.1  Features 

The  digital  inputs  of  the  Orion-M  can  be  configured  as  alarm  inputs  with  adjustable  delay  timers,  as  control 
inputs for controlling profile operation or for direct control of the system’s digital outputs. 
 
The digital outputs of the Orion-M can be used as direct outputs for controlling external equipment related to 
the application through software switches, called events, or be programmed to act as system alarm or status 
outputs.  All outputs have adjustable delay times for on, off and cycle times. 
 
The Orion-M can be operated in single set point or automatic profile control mode.  Profile entry is made easy 
through  the  use  of  copy,  paste  and  delete  menu  selections.    Profiles  can  be  copied  to  the  external  ‘USB’ 
memory  stick  and  then  imported  to  another  Orion-M  controller  which  eliminates  the  need  to  enter  duplicate 
profiles into multiple Orion-M systems.  When running in automatic profile mode, the operator can place the 
system  into  hold  and  change  any  control  parameter  without  modifying  the  saved  profile.  This  gives  the 
operator maximum flexibility over the controlled process. 
 
Data file analysis tools (auto-trend) make looking at historical data a simple task.  Any control variable saved 
to  the  Orion-M  flash  memory  can  be  plotted  on  the  historical  data  trend,  for  any  time  frame  within  the  data 
file’s total time range.  Full ‘USB’ print capabilities from the Orion-M interface to a standard HP inkjet printer 
Model 6540, 6940, 6980 (or compatible printer), eliminates the need for a PC, strip or circular chart-recording 
device.  Graphics trends, historical and report print functions are standard.    
 
The built in Ethernet functionality includes a ‘Web Server’ to provides access to all Orion-M data (view only), a 
VNC  interface  for  remote  control  and  monitoring  and  an  NTS  clock,  all  available  via  a  local  Intranet 
connection  (wired  or  wireless),  or  the  World  Wide  Web  using  standard  software  like  Microsoft’s  Internet 
Explorer. 
 

Содержание Orion-M

Страница 1: ...Orion M Honeywell UDC2500 3200 Series Controller System Guide Rev C February 7 2011 Supersedes Rev B March 25 2010 Orion M Honeywell UDC2500 3200 Controller System Guide...

Страница 2: ...ion to verify that your selections are consistent with your application inputs outputs alarms limits etc If the problem persists after checking the above you can get technical assistance by dialing 1...

Страница 3: ...1 1 Communications Wiring 2 1 3 Configuring the Honeywell UDC2500 3200 Controller 3 1 3 1 Assigning the Proper Communications Settings 3 1 3 2 Input Type Assignments 3 2 3 2 1 Input 1 Operation 3 2 3...

Страница 4: ......

Страница 5: ...No other control system on the market provides the flexibility functionality and configurability of the Orion M 1 1 Features The digital inputs of the Orion M can be configured as alarm inputs with a...

Страница 6: ...includes the following interface features Overview screen that displays all runtime information Profile run and monitor views Profile entry open save and download interface screens Current alarm and a...

Страница 7: ...ring to and form the UDC controllers be routed away from all high voltage and or output control wiring This will minimize the chances of electrical transients or spikes in the power control wiring fro...

Страница 8: ...UDC2500 or UDC3200 Product Manual for all other connections including power sensor and control wiring Since no two applications are the same it is up to the system designer to insure that the control...

Страница 9: ...munications link beginning with 1 up to the total number of controllers As control loops are enabled in the Orion M Configurator the Orion M will automatically use the Loop Input as the corresponding...

Страница 10: ...he Orion M Configurator the temperature units in the Orion M must match the UDC controllers for the drybulb wetbulb calculation to be performed correctly If the temperature units do not match the rela...

Страница 11: ...f the loop control is visible to the operator it is recommended that the Monitor Input Offset screen be hidden see Section 3 6 Orion Functions Startup View in the Orion M Configuration Manual or even...

Страница 12: ...M is designed to send the shed timer reset command to the UDC controller to take it out of computer set point control when the set point permission is enabled This allows control via the keypad of the...

Страница 13: ...Orion M APPENDIX FDC Orion M A 1 Appendix...

Страница 14: ...ter delivery to the first purchaser for use There are no expressed or implied Warranties extending beyond the Warranties herein and above set forth Limitations Future Design Controls provides no warra...

Отзывы: