85
System manual
VAIE 4000 Compact Systems
EN
VAIE
4000
10. TECHNICAL SPECIFICATIONS
MODELLO
VAIE4101
VAIE4102
VAIE4251
VAIE4252
Rated audio output @230 Vac
100 W
250 W
Rated audio output @24 Vdc
85 W (THD=10%)
200 W (THD=10%)
Rated audio output @21,5 Vdc
68 W (THD=10%)
158 W (THD=10%)
Display
4.3” , backlit with touch screen, 480x272 pixels
No. of zones/amplifiers
1
2
1
2
Inputs
Emergency microphone
• Sensitivity / Impedance
• Frequency response
• S/N ratio
Dynamic XLR-F w/P.T.T. (Push To Talk) on the front door
Signal level: 20 mV / 10 kΩ
110 ÷ 10.000 Hz
61 dB
Paging / Emergency units (UNIT)
• Sensitivity / Impedance
• Frequency response
• S/N ratio
1 off Rj45 for paging units (PA) or emergency units (VES)
Signal level: max. 850 mV / 8 kΩ
60 ÷20.000 Hz
84 dB
AUX INPUT (LINE VOX) / MUSIC
• Sensitivity / Impedance
• Frequency response
• S/N ratio
Balanced with terminals (HOT-COM-GND)
Programmable in ON / OFF / VOX with A.P.T. modes
Precedence input with contact closing activation
160 mV / 40 kΩ
40 ÷ 20.000 Hz
73 dB
Outputs
Constant voltage outputs
1 zone A/B
for 100V lines
Minimum 100 Ω
2 zones A/B
for 100V lines
Minimum 100 Ω
1 zone A/B
for 100V lines
Minimum 40 Ω
2 zones A/B
for 100V lines
Minimum 40 Ω
Emergency controls
• Controlled inputs (
IN1÷IN4
)
• Outputs
R1
,
R2
Programmable for
normally active
or
normally inactive
state
4 off inputs with diagnostic
2 off relays for signalling, state of emergency and faults (24 Vdc / 1 A each)
N.O-N.C-Exchange
state
General information
Mains power supply
Consumption @230 Vac
230 V
ac 50/60Hz +10/-15%
130 W full load / 22 W quiescent
330 W full load / 33 W quiescent
Secondary power supply
Consumption @24 Vdc
24 V
dc (2x 12 Vdc batteries)
4,2 A full load
660 mA quiescent
0,22 A
energy saving
9,8 A full load
940 mA quiescent
0,22 A
energy saving
Batteries (see page 34 for details)
12 Ah - Ri max. 250 m
Ω
24 h in s 1/2 h with full power alarm message
18 Ah- Ri max. 167 m
Ω
72 h in s 1/2 h with full power alarm message
Charger / Power supply unit
2.5 A (I max. a)
5 A (I max. b)
9 A (I max. a)
11 A (I max. b)
21 V (final voltage – detached battery)
27,2 V (complete load voltage)
Internal fuses
V~ 2AT
L
/ V 10AT
L
Environmental operating conditions
Temperature: +5°C ÷ +40°C | Relative humidity: 25% to 75% (non-condensing)
Type of mounting
Wall mounting
Dimensions (W x H x D)
360 x 495 x 193 mm
Net weight (without batteries)
11,5 kg
- - -
___