XL-20 Owner’s Manual - Page 7
allowing full access throughout the interior.
8) BYPASS BUTTON
The BYPASS button is used to temporarily exclude protection of a specific zone.
9) INSTANT BUTTON
The INSTANT button enables arming the system eliminating entry/exit delays. If
enabled with the STAY button, it enables arming the system in the STAY/
INSTANT mode. NOTE: The INSTANT modes are enabled in question #05,
location 2.
10) CODE BUTTON
The CODE button is used to enter the installer programming mode and entry of
user codes.
11) KEYPAD AUXILIARY KEYS
Pressing the two keys (top & bottom) labeled "P" at the same time initiates a CS
transmission, if programmed, of PANIC, AUXILIARY or FIRE, annunciates the
keypad sounder and turns on the bell output. If not programmed to transmit, these
keys can only result in a local warning as follows (see question 05, location 1):
Keypad Sounder - Steady for PANIC, Pulsing for FIRE and AUXILIARY
Bell Output - Steady for PANIC, Pulsing for FIRE
12) TX LB LED
This LED will pulse whenever any RF transmitter has a low battery. Also, the
corresponding zone LED for that transmitter will pulse.
13) RF SPVR LED
This LED will indicate three different RF supervisory conditions and one bell
output supervisory condition as follows:
No supervision conditions exist (normal)
ON RF transmitter has not checked in for more than 12 hours
BLINKING (fast) RF transmitter reports a tamper condition
BLINKING (slow) Bell Output is in supervision