39
LCD DISPLAY MESSAGES
(# stands for the barrel number which is L, C, R, or 1, 2, 3, 4)
FBD56X SERIES FROZEN BEVERAGE DISPENSERS
MESSAGE DESCRIPTION
Sleep
Unit in “Sleep” mode. Unit is shut down.
CmpSDl
This delay is before compressor starts. The time period varies from 1 to 20 seconds.
CmpStr
This is displayed when compressor starts freezing or defrosting.
CmpRun
This is displayed only on Left Side, when compressor is running.
DEF-WT
This side is waiting to defrost.
DEFBtr
If “DEF” is pressed and if the beater has not been running, then this is displayed.
DEFCWt
Time delay while the compressor is starting.
Defrst
This is displayed when side is DEFROSTING.
DEFSpd
This is displayed when a side has been interrupted by the other side freezing. After the other side
has frozen down, then defrost is resumed.
RunOff
This is displayed when freeze is off or when the side is turned off.
RunHGW
This is displayed on the opposite side when a side has defrosted and is waiting to refreeze or when
one side is defrosting and the other side is in Run Thaw Mode.
RunCWt
This is displayed, prior to starting a freeze down; this is a time delay when the compressor is
starting.
RunFW
This is displayed after the freeze down has finished.
RunFrz
This is displayed when a side is freezing down.
RunThW
This is displayed after the Thaw percent has been reached.
RunTha
This is displayed when a side is Thawing before refreezing.
RunB
If “Run” is pressed and if the beater has not been running then this is displayed for a maximum time
delay of two (2) minutes.
FilOff
The unit will not fill with product when this is displayed.
LFillH
This is displayed during first freeze. The pressure in the chamber has not dropped below the fill
pressure.
Fill H
This is displayed during normal operations when the pressure in the chamber has not dropped
below the fill pressure.
LfPCO2
This is displayed prior to filling the chamber with solution. This only allows CO
2
into the chamber
for a specified time period.
LfCO2S
This is displayed prior to filling the chamber with solution. This only allows CO
2
and solution to fill
the chamber until four (4) psig is reached in the chamber.
LFill
This is displayed during first freeze. The unit is filling the chamber.
Fillng
This is displayed during normal operations when the chamber is filling.
Содержание FBD562
Страница 49: ...49 14 8 LOWER BOARD SCHEMATIC FBD 562 562 ELECTRICAL BOX SCHEMATIC ...
Страница 50: ...50 14 9 UPPER BOARD SCHEMATIC FBD 563 563 SCHEMATIC UPPER BOARD ...
Страница 51: ...51 14 10 LOWER BOARD SCHEMATIC FBD 563 563 ELECTRICAL BOX SCHEMATIC ...
Страница 52: ...52 14 11 UPPER BOARD SCHEMATIC FBD 564 564 SCHEMATIC UPPER BOARD ...
Страница 53: ...53 14 12 LOWER BOARD SCHEMATIC FBD 564 564 ELECTRICAL BOX SCHEMATIC LPB1 ...
Страница 55: ...55 THIS PAGE INTENTIONALLY LEFT BLANK ...