![FBD FBD553D Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/fbd/fbd553d/fbd553d_installation-operation-and-service-manual_547020007.webp)
4
Figure 6.1
C. Splice a barb "cross" into the CO
2
supply line and run two (2) lines to the syrup pump CO
2
inlets.
Or
If Figal tank will be utilized, splice a barb "cross" into the CO
2
supply line and run three (3) lines
to tank location and install CO
2
tank couplers to end of lines.
D.
Do not turn on the CO
2
at this time.
5.3
SYRUP SUPPLY
The unit may be connected to either a BIB (Bag-in-Box) or a five-gallon syrup supply (figal). Use
the appropriate connection method below.
NOTE
Installations requiring long runs of tubing [25 feet or more (7.62 meters)] may encounter pressure
fluctuation problems. The machine's sensors may indicate that the machine is out of syrup, water,
or CO
2
. To avoid pressure fluctuations, consider the following solutions.
A. Increase the tubing size to 3/8 inch diameter.
B. Install booster pumps in the supply lines. Use a vacuum regulating valve with syrup booster
pumps.
C. Increase primary CO
2
regulator pressure from bulk or tank CO
2
to 105 - 120 PSIG (723.9 to
828.0 KPa). A secondary regulator WILL be necessary for syrup pumps to avoid exceeding
manufacturer’s recommended operating pressures. Set the secondary regualtor to 70-72 PSIG
(482.6 to 496.4 KPa).
BIB SUPPLY
A. Fabricate three (3) 1/4 inch supply lines for connecting the unit to the syrup pumps.
B. Connect the lines to the bulkhead fittings labeled "SYRUP LEFT", "SYRUP CENTER" and
"SYRUP RIGHT" located at the rear of the unit (see Figure 5.2).
C. Do not turn on the CO
2
at this time.
FIVE GALLON (FIGAL) TANK SUPPLY
A. Fabricate three (3) 1/4 inch supply lines for connecting the unit to the syrup tanks.
B. Connect the lines to the bulkhead fittings labeled "SYRUP LEFT", "SYRUP CENTER" and
"SYRUP RIGHT" located at the rear of the unit (see Figure 5.2).
C.
When using five gallon (figal) syrup tanks, a Syrup Restart Valve (SRV) and tank couplers
must be used on each line. Warranties will be void if an SRV is not installed.
1.
The "OUT OF" devices in the machine will not function properly without the use of a Syrup
Restart Valve. If the "OUT OF" devices do not function, the machine will supply only water
to the product cylinder and it will freeze up.
2.
When replacing a figal, insure that the syrup line to the dispenser is attached to the figal
before the CO
2
line is attached to the figal. This will allow the SRV to work properly.
3.
To operate the SRV, press the restart button after syrup tank is changed. The red light
beside each chamber will then go out and product will refreeze.
D.
Do not turn on the CO
2
at this time.
6.
STARTING THE UNIT
6.1
INITIAL POWER-UP
A. Insure the electrical power is disconnected from the
unit.
B. Open front marquee door, if installed, by firmly
pulling back at the bottom and rotating up and over.
C. Using a Phillips head screwdriver, remove the
stainless steel access panel located below the
keypad.
D. Remove the splash plate and electric box cover
(see Figure 6.1).
E. Plug unit in to the electrical power. Check for the display of information on the LCD control panel
(this will read "COPYRIGHT" on bottom line of LCD display).
COVER