B.
Before making any changes to the level control settings, defrost all three chambers by
pressing the “DEF” buttons located on the control panel. The machine may
automatically correct any problems with drink quality after going through a defrost cycle.
C. After the defrost cycle, the compressor may cycle on and off several times to ensure that the
product is uniformly frozen.
Wait several minutes before judging the quality of the product.
D. If factory level control settings are correct, the product should freeze, thaw and then refreeze to
an acceptable consistency range.
Remember, drinks poured directly after a freeze cycle will
appear more frozen than the last drink poured before the unit begins to refreeze the cylinder.
E. The level control settings of each drink chamber are preset to a default value of 3. If the
corresponding secondary regulator inside the unit is properly set to 28-32 PSIG (193.0 to
220.8 KPa), the chamber pressure will be “set” automatically.
F.
After the machine is installed and each chamber is properly filled, press the “DEF” button on the
control panel to allow the machine to automatically “baseline”. Baselining indicates to the
machine that the chamber contains liquid. As a result, the machine sensors determine how
much to freeze the product.
G. The display will flash “DEFROSTING” until baselining is complete. The machine will
automatically start running if the machine was running when the defrost cycle was started. If the
machine was not running before the defrost cycle started, the “RUN” button must be pressed.
Note that there may be a delay of up to two (2) minutes before the machine turns on after the
“RUN” button is pushed.
This delay is normal. Do not press the
“RUN”
button again or press
any other buttons until the machine starts.
10.2 DRINK TOO HARD AND COLD
A. If the drink is too hard and cold or the chamber is not full, adjust the “level control” to a higher
level setting. Use the recommended settings that follow to properly adjust the liquid level
control settings.
B. It will be necessary to drain off several drinks to allow the chamber to fill and rebalance. It is
also then necessary to defrost the chamber and allow the product to refreeze. If the drink is still
too hard, repeat the process taking the level control setting to the next higher value.
10.3 DRINK TOO LIQUID
A. If the drink is cold, but is still a liquid, adjust the level control to a lower level setting. Use the
recommended settings that follow to properly adjust the level control.
B. It will be necessary to drain off several drinks to allow the chamber to fill and rebalance. It is
then necessary to defrost the chamber and allow the product to refreeze. If the drink is still too
liquid, repeat the process taking the level control to the next lower setting.
C. If the product is still too liquid, it may be necessary to adjust the THAW-FREEZE beater settings.
Refer to Section 11 (Changing Factory Thaw and Freeze Settings).
D. Drink temperature should be between 24°F and 28°F (-4.4°C to -2.2°C).
NOTE
If "Wet" or "Dry" drinks are common to all three chambers, adjust "Regulated CO
2
" up to
lighten drink or down to make drink wetter before adjusting level controls!
17
HIGHER LEVEL SETTING
HIGHER LEVEL SETTING
HIGHER LEVEL SETTING
FACTORY SETTING
LOWER LEVEL SETTING
LOWER LEVEL SETTING
LOWER LEVEL SETTING
6
5
4
3
2
1
0
MORE LIQUID
"DRY" OR MORE
FROZEN
Recommended “Level Control” Settings
Figure 10.1