9.2 Engine malfunctions
Fault
Possible cause
Remedy
Engine does not
start
Fuel tank empty
Check, refill if necessary
Fuel valve closed
Open the fuel valve
Fuel system clogged
Cleaning the fuel strainer
Check the fuel strainer in the carburettor
Have it checked by qualified expert per-
sonnel
Engine stop switch in position “OFF”
Engine stop switch in position “ON”
Engine oil level too low
Check the engine oil level, top up if nec-
essary
No ignition spark
Clean the spark plug, replace if neces-
sary
Engine stop switch defective
Have it checked by qualified expert per-
sonnel
No fuel in carburettor
Check the fuel supply
Have it checked by qualified expert per-
sonnel
Engine does not
crank when oper-
ating the recoil
starter
Recoil starter defective
Replace the recoil starter
Spring broken
Replace the recoil starter
Starter rope of
recoil starter does
not return to initial
position
Recoil starter dirty
Clean the recoil starter
Insufficient pretension of the spring
Check the pretension of the spring, adjust
if necessary
Spring broken
Replace the recoil starter
Low engine power
Air filter clogged
Clean the air filter, replace if necessary
Throttle cable defective
Have it checked by qualified expert per-
sonnel
Engine defective
Have it checked by qualified expert per-
sonnel
Carburettor defective
Have it checked by qualified expert per-
sonnel
Engine overheats
Lack of cooling air
Clean the air filter, replace if necessary
Cleaning the cooling fins and the cooling
air intake openings
Engine stops
Fuel system clogged
Cleaning the fuel strainer
Check the fuel strainer in the carburettor
Have it checked by qualified expert per-
sonnel
Fuel tank empty
Check, refill if necessary
Troubleshooting – Engine malfunctions
DFP9
99
Содержание Dynapac DFP9
Страница 6: ...Table of contents DFP9 6 ...
Страница 7: ...1 Introduction Introduction DFP9 7 ...
Страница 11: ...2 Technical data Technical data DFP9 11 ...
Страница 15: ...3 Concerning your safety Concerning your safety DFP9 15 ...
Страница 39: ...4 Indicators and control elements Indicators and control elements DFP9 39 ...
Страница 45: ...5 Checks prior to start up Checks prior to start up DFP9 45 ...
Страница 52: ...Checks prior to start up Checking the water level topping up DFP9 52 ...
Страница 53: ...6 Operation Operation DFP9 53 ...
Страница 63: ...7 Loading transporting the machine Loading transporting the machine DFP9 63 ...
Страница 67: ...8 Maintenance Maintenance DFP9 67 ...
Страница 97: ...9 Troubleshooting Troubleshooting DFP9 97 ...
Страница 103: ...10 Disposal Disposal DFP9 103 ...
Страница 105: ......
Страница 106: ......