![Fayat Dynapac DFP9 Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/fayat/dynapac-dfp9/dynapac-dfp9_operating-instruction-maintenance-instruction_546868089.webp)
7.
Tilt the machine to the opposite side and secure it properly.
8.
Screw the drain plug back in.
NOTICE!
Components may get damaged!
Do not use low-ash engine oils for the exciter shaft
housing.
fuels and lubricants’ on page 71
9.
Fill in oil.
10.
Stand the machine horizontally and check the oil level.
ð
The oil level must reach the bottom edge of the filler
opening.
11.
Screw the filler plug back in.
12.
Dispose of oil in line with environmental regulations.
B-834-0304
Fig. 94
B-834-0303
Fig. 95
Maintenance – Annually
DFP9
89