Maintenance
– Special instructions
98
4812325559EN
2018-02-20
POINT 2
– Fan drive pressure measurement point. It is located
on the rear chassis, at the right side, on the engine's cap (1
st
point from the rear to the front part).
Measurement pressure: 100 bar (1,450 psi) with the fan
working at 2,200 RPM.(to realize measurement press
the Engine radiators assembly cleaning button
)
POINT 3
– Fan drive pressure measurement point. It is located
on the rear chassis, at the right side, on the engine's cap (2
nd
point from the rear to the front part).
Measurement pressure: 280 bar (4,061 psi) with the fan
working at 2,200 RPM (to perform the measurement
disconnect the fan pump solenoid)
POINTS 4 & 5
– Radiator pressure measurement point. It is
located on the rear chassis (input and output), at the right side,
on the engine's cap (3
rd
and 4
th
points from the rear to the front
part).
Measurement maximum pressure: 4 bar (60 psi) with
the fan working at 2,200 RP
POINT 6
– Blade pressure measurement point. It is located on
the front chassis, at the right side, next to the joint.
Measurement pressure: Maximum of 140 bar (2,030
psi)
2
3
4
5
Fig.
– Measurement points 2,3,4 and 5
6
Fig.
– Measurement point 6
Fig.
– Fan pump solenoid