9.3 Starting the engine with jump leads
NOTICE!
A wrong connection will cause severe damage
in the electric system.
–
Bridge the machine only with a 12 Volt auxiliary
battery.
1.
Remove the battery box cover.
2.
First connect the plus pole of the external battery to the plus
pole of the starter battery using the first jump lead.
3.
Next, connect the second jump lead to the minus pole of the
energizing external battery and then to the minus pole of the
starter battery.
4.
Start the engine
Chapter 6.2 ‘Starting the engine’
5.
After starting disconnect the minus poles first and the plus
poles after.
6.
Assemble the battery box cover.
Fig. 132
Troubleshooting – Starting the engine with jump leads
DRP25D
109
Содержание DYNAPAC DRP25D
Страница 6: ...Table of contents DRP25D 6...
Страница 7: ...1 Introduction Introduction DRP25D 7...
Страница 11: ...2 Technical data Technical data DRP25D 11...
Страница 15: ...3 Concerning your safety Concerning your safety DRP25D 15...
Страница 40: ...Concerning your safety Safety components DRP25D 40...
Страница 41: ...4 Indicators and control elements Indicators and control elements DRP25D 41...
Страница 47: ...5 Checks prior to start up Checks prior to start up DRP25D 47...
Страница 53: ...6 Operation Operation DRP25D 53...
Страница 60: ...Operation Parking the machine in secured condition DRP25D 60...
Страница 61: ...7 Loading transporting the machine Loading transporting the machine DRP25D 61...
Страница 66: ...Loading transporting the machine Transport wheels DRP25D 66...
Страница 67: ...8 Maintenance Maintenance DRP25D 67...
Страница 80: ...9 Assemble the battery box cover B 692 0038 Fig 72 Maintenance Semi annually DRP25D 80...
Страница 93: ...12 Assemble the recoil starter 2 with fastening screws 1 Fig 103 Maintenance Annually DRP25D 93...
Страница 105: ...9 Troubleshooting Troubleshooting DRP25D 105...
Страница 115: ...10 Disposal Disposal DRP25D 115...
Страница 117: ......
Страница 118: ......