ENGLISH
4.
P
ROGRAMMING
4.1.
Coin Acceptor
Information on programming the money accepted by the electronic coin acceptor can be found in the coin acceptor
manual, provided separately.
First set the time of the service as described in chapter 4.2, then set the coin acceptor as outlined in the coin acceptor manual.
In the absence of power supply voltage, the coins introduced in the electronic coin acceptor will be rejected.
4.2.
Time of service
In Fig 5 identify the DIP-Switches with the word TIME on them.
Set the DIP-Switches as shown in Table 1 – TIME (page 2) in order to obtain the desired time.
With a multi-coin acceptor the time of the service corresponds to the time set for the coin of least value. Times for coins of
greater value depend on the settings of the coin acceptor. To set the coin acceptor please follow the instructions outlined in
the coin acceptor manual.
4.3.
Accumulation of time
The
CT1
comes already programmed with the Accumulation function activated. This means that more than one coin
can be inserted consecutively in order to accumulate more time.
The DIP switch 8 (ACCU in Fig 5) activates or deactivates the accumulation of time as indicated below.
Accumulation activated.
Each coin inserted will have an increase in time equal to the value set in paragraph 4.2; once
24 hours is exceeded, no further coins will be accepted until the remaining time returns to less
than 24 hours.
Accumulation
deactivated.
A single coin is accepted which will activate service. Any other coins inserted before the service
has ended will be rejected.
4.4.
Delay of service
The delay of service can be useful for allowing customers sufficient time to reach the service area or to prepare
themselves before using the service. In the case of showers, it can be useful for allowing sufficient time to reach the
shower or to undress before entering.
In Fig 5 identify the DIP-Switches with the word DELAY on them.
Set the DIP-Switches according to the tables below to obtain the delay time desired.
DIP-Switch
Time
[seconds]
DIP-Switch
Time
[seconds]
DIP-Switch
Time
[seconds]
DIP-Switch
Time
[seconds]
0s
10s
30s
50s
5s
20s
40s
60s
4.5.
End of service notice
The DIP-SWITCH 4 (PRE in Fig 5) activates or deactivates the end of service notice as indicated below.
Notice activated
The service is interrupted for 2 seconds when the remaining time is 1 minute.
Notice deactivated.
The service remains activated for the entire programmed time.
4.6.
Start or stop the service manually
The LOAD ON/OFF button found on the electronic board (Fig 5) allows you to alternately start or stop the service. This
is useful for service testing and maintenance on part of the operator. It also allows to zero the loaded time, after the
introduction of coins for testing.
F
AVERO
E
LECTRONIC
D
ESIGN
Pag. 7 / 32
178-10-M02 - CT1 manuale di uso e installazione