8th edition, 9-11-2018
7000.05038, 8th edition, 9-11-2018
7000.05038
Installation
16
4.2
Electrical connection
4.2.1
Notes on the electrical connection
NOTICE!
Electrostatic discharges to the Motion Controller connections can damage the electronic
components
Observe the ESD protective measures.
NOTICE!
Incorrect connection of the wires can damage the electronic components.
Connect the wires as shown in the connection assignment.
NOTICE!
Excessive force can damage the flexboard.
Do not press in the plug connectors by force.
Use a suitable tool (tweezers, flat-nose pliers) if necessary.
Do not pinch the flexboard.
4.2.2
Screening
Fig. 3:
MCBL motor wiring
The encoder and signal cables are susceptible to interference. Therefore, a maximum
cable length cannot be specified.
Shielded wires must always be used with cable lengths > 300 mm.
Cable Shield
Motor A
Phase A
Sensor C
Hall Sensor C
Sensor A
Hall Sensor A
Motor B
Phase B
U
DD
Sensor B
Hall Sensor B
Motor C
Phase C
Brushless
DC-Servomotor
SGND
Cable Shield