4.3
Electromagnetic compatibility (EMC)
Follow the instructions in the following chapters to perform an EMC-compliant installa
-
tion.
WARNING!
!
The MCS can cause high-frequency interference which can affect the function of electronic
implants and other electronic devices.
Take appropriate interference suppression measures, particularly during use in residen
-
tial environments.
Observe the notices for EMC-compliant setup.
NOTICE!
Drive electronics with qualified limit values in accordance with EN-61800-3: Category C2
can cause radio interference in residential areas.
For these drive electronics, take additional measures to limit the spread of radio inter
-
ference.
4.3.1
Functional earthing
DANGER!
!
Danger to life through ground leakage currents
≥
3.5 mA
Check the grounding of the devices for proper installation.
The grounding system is essential for discharging parasitic current and for a potential distri
-
bution in the system that is as uniform as possible. The most efficient systems have a star or
mesh shape. A star-shaped connection is easier to implement.
Ensure an adequate cross section and a very good electrical ground connection so that
the contact resistances are low not only for the low-frequency currents.
The ground connection can be improved, e.g., by removing the oxide layers from the
ends of conductors with fine sandpaper.
For electrical safety:
Ground in accordance with current standards and guidelines.
Use separate protective conductors (PE) for all necessary parts (e.g., mains supply,
motor, controller).
Keep grounding cable as short as possible.
For functional earthing:
Use a braided shield that is meshed as tightly as possible.
Direct contact with the grounding plate is to be preferred.
Therefore, avoid contact with the controller and then with the grounding plate.
Connections made over a large surface area are to be preferred.