![FATEK FBs Series Скачать руководство пользователя страница 195](http://html1.mh-extra.com/html/fatek/fbs-series/fbs-series_manual_3764826195.webp)
Advanced Function Instruction
7 -3 1
FUN55
D
P
B
→
G
BINARY - CODE TO GRAY - CODE CONVERSION
FUN55
D
P
B
→
G
Example 2: When M0 =1, it will be perform the 32-bit code conversion
S :
D : R100
R0
M0
EN
55DP.B G
˙
Converting the 32-bit Binary-code in DR0 into Gray-code,
and then storing the result into DR100.
DR0
=
00110111001001000010111100010100B
Î
DR100
=
00101100101101100011100010011110B