A power socket with ACS00057 contacts is used to connect power through XP25 (supplied with the
module, see Table 1-2).
Fig. 3-19: XP25 Power Connector
Table 3
-
14: The Designation of XP12 Power Connector Contacts
3.4.11
Discrete Input/Output Port
The discrete input/output port has 8 separately programmable input/output lines. In output mode,
each line is a push-pull type output having the following parameters:
Table 3
-
15: Discrete Input/Output Port Line Parameters in Output Mode
Designation
Description
Minimum value
Rated value
Maximum value
I
OL
Low-level output
current
8 mA
14 mA
-
V
OH
High-level output
voltage
2.6 V
3.3 V
-