Warning

Warning

Warning!

Install the XTT filter disk (72) nearest the user.

Install the XTT filter disk in the disk holder as shown in Fig. 7.

Introduce the clean XTT filter disk again into the disk support (75).

Screw in tight again the covering plate (98).

Hold the disk support in such a way, that the covering plate (98) shows in direction of the tripod.

Push the disk support, beginning from the foot side, into the gap, so that the flap (96) slides in the gap of the

covering plate.

Now the XTT filter disk press the micro-switch (97) into for the BreakSafe protection and the electri

cal circuit is closed. Therefore the XTT-filter disk is secured with BreakSafe.

Turn the screws (74) into and place the acrylic sheet lounger (1).

For replacement of the high pressure burners please turn to your specialized dealer or to the manufacturer of the

unit.
No responsibility will be taken over, whenever other than the genuine high pressure burners are installed.

6.3 Exchanging the illumination light (78, picture 3)

Take up the acrylic sheet lounger (1) on the foot a little bit, and pull away thereunder to the front direction the small

covering plate (57, picture 4). Then turn the illumination light (78) in any direction you with to for about 90 degrees,

until the contact pins (80) in the slot of the holder (81) are visible. Pull out the light. Hold the new bulb horizontally,

so that the contact pins lay horizontally one behind the other. In this position press the light bulb into the holder. Turn

the bulb for about 90 degrees, until the holder engages into. Place on again the covering plate (57).

6.4 Exchanging the Filter Mats

The air for cooling the unit is fed through micro filter mats on entry to the unit. Fluff, hair, dust particles, etc. are

filtered out in the filter so that it is only necessary to clean the components inside the unit e.g. such as filter plates

infrequently. The particles filtered out eventually clog the filter after extended use and thus reduce the effectiven-

ess of the cooling of the unit. Therefore the filter mats should be renewed from time to time to avoid the unit

overheating. The interval between changes is dependant on the operating time and the amount of dirt.

Check up the filters in any case every 200 hours of operation. If the pores of the filters are half

Blocked, the filter must be exchanged.

Only use original filter mats from your specialist dealer or unit manufacturer.

Exchanging the Filter Mats of the footrack (picture 4)

Take up a little bit the acrylic sheet lounger (1) at the foot and pull away thereunder to the front direction the

small covering plate (57). Inside of the covering plate the filter mat (82) is fastened with strip fastener. Take

away the filter mat and place on again the new filter mat.

Exchanging the Filter Mats of the tanning arm (picture 3)

Remove the waved covering plate (83) on the respective tanning arm. For this purpose, push it in longitudinal

direction, until it slides with its flaps out of the large covering plate (66). Then pull out the wire clip (85), with

which the filter mats (86) are being supported. Remove the old filter mat and insert the new filter mat. Insert

again the wire clip. Place again the covering plate (83).

7 ADVICES

Replacement of the high pressure burner

The performance of the high pressure burner gradually reduces without this being visually noticeable. You

must level this out with a longer sunbathing time. uwe recommends to exchange the high pressure burner after

approx. 400 hours of operation.

Pipeframe

The two feet of the pipeframe (2) showing in direction of the assembly plates can be taken away one by one.

So that for service jobs you can easily reach the assembly plates, without having to disassemble the unit.

Содержание SunBoard XTT

Страница 1: ...1 INDOOR TANNING EQUIPMENT CARE USE AND INSTALLATION INSTRUCTIONS Model SunBoard XTT PC MARKETING 1040 WILT AVENUE RIDGEFIELD NJ 07657 1 800 FAST TAN...

Страница 2: ...4 1 5 Product Liability 4 1 6 Emergency Procedure 4 1 7 Explanation of Danger Symbols 4 2 OPERATION I INFORMATION FOR THE USER OF THE UNIT 5 6 2 1 Starting to sunbathe 5 2 2 Important Technical Detai...

Страница 3: ...week onward USE PROTECTIVE EYEWEAR WHENEVER THE EQUIPMENT IS ENERGIZED READ THE INSTRUCTION BOOKLET BEFORE USING THIS PRODUCT WARNING If you have been diagnosed by a physician as being allergic to th...

Страница 4: ...TE AND ARE DESIGNED FOR USE WITH INDOOR TANNING EQUIPMENT FAILURE TO COMPLY WITH RECOMMENDATIONS AND WARNINGS STATED ABOVE MAY VOID THE MANUFACTURER S WARRANTY WARNING THIS UNIT MUST NOT BE USED IF TH...

Страница 5: ...ilter disc when exchanging the burner the electrical circuit will be interrupted and the unit can not be started see Section 8 BreakSafe Speakers 34 picture 3 There are two speakers so that you can en...

Страница 6: ...on the pallet The Plexiglas plate lounger 1 picture 4 lies free on top of the pipeframe 2 Lift down the Plexiglas plate together with someone If the pipeframe is fastened together with the tripod unwi...

Страница 7: ...the tripod Secure the screws 28 of the foot casing with toothed disks A8 4 29 and octagonal nuts M8 30 secure the screws 31 of the light casing with washers 32 having 25 mm in external diameter and w...

Страница 8: ...the support 44 of the covering hood 40 After this secure coming from the tripod the four pins 64 with disks 46 having an external diameter of 25mm and with hexagonal nuts 45 You really must tighten u...

Страница 9: ...the right side of the tripod This tanning arm has an 18 poled cable X6 53 with plug and the BreakSafe cable X6a these cables you have to pull through down wards into the footrack The plug X6 53 will...

Страница 10: ...to the tripod Then arrange the three covering hoods 56 57 58 around the pipeframe The two covering hoods 56 and 58 arranged on the sides of the pipeframe will be fixed onto the tripod by a strip faste...

Страница 11: ...ffective ventilation can be found in the brochure AIR CONDITIONING TIPS which is available from your dealer or from us 3 4 Electrical Connection Important The connection work may only be done by an el...

Страница 12: ...e even We reserve the right to make technical changes LAMP CONFIGURATION If the lamps are not placed in the correct position this may result in a loss of performance and lifetime Please ensure to use...

Страница 13: ...ents Provide protective glasses and ensure that they are used Highlight the need to adjust the length of the sunbathing period depending on skin type Keep user instructions at hand Put up the safety i...

Страница 14: ...n the acrylic sheet with important information Please note the information and then remove the sticker Do not operate units without acrylic sheets because otherwise the cooling of the lamps is no long...

Страница 15: ...int on both sides Pull off the disk holder from the front using both hands Hold the high pressure lamp by the rectangular base and press it out of the socket Cleaning the Reflector Clean the reflector...

Страница 16: ...ng the High Pressure lamp Hold the new high pressure lamp by the base 102 Insert the lamp into the holder 77 Attention The contact pins 79 of the socket have different diameters Please insert accordin...

Страница 17: ...ilter so that it is only necessary to clean the components inside the unit e g such as filter plates infrequently The particles filtered out eventually clog the filter after extended use and thus redu...

Страница 18: ...k holder 75 picture 7 and the reflector 87 If this does not help there is an electrical defect in the unit Checking up by uwe or by another firm named by uwe The illumination light does not shine exch...

Страница 19: ...ses They should not be thrown together with the regular waste The local offices will inform you where the burner could be properly wasted Unit Faulty units should be disposed of according to local reg...

Страница 20: ...20 ID NR 265 360 03 03 PC MARKETING 1040 WILT AVENUE RIDGEFIELD NJ 07657 1 800 FAST TAN...

Отзывы: