ENTER LIBRARY PRO-
GRAMMING MODE.

Press and hold the P key for 3

seconds.

Type in 3 2 2 8 using the

product keys. Press the P key.

Press the down arrow key.

Press the down arrow key to

select either PRODLIBR OR AL-

RMLIBR.

Choose either PRODLIBR

(Product Library) or ALRMLIBR

(Action Alarm Library) by

pressing the P key.

EXIT LIBRARY PRO-
GRAMMING.

Press the up

or down arrow keys until dis-

play reads EXIT.

A flashing dash will be dis-

played. Press the SCAN key

and use the product keys to

spell a new word. Press the

right arrow key to advance to

the next character position.

Continue spelling the word.

When done, press the P key.

Press the P key. 

SYSTEM 3228
STORE MANAGER

PROGRAM will be displayed.

Press the P key.

TO SAVE WORD, 

press P

again. Skip to Exit Library Pro-

gramming.

To CANCEL or MoDIFY

,

see next step.

TO CANCEL OR MODIFY
WORD, 

press the left or right

arrow keys to select CANCEL

or MODIFY.

Press the P key to EXIT and

cancel the word. 

Press the SCAN key to go

back and modify the word. 

IF YOU CHOOSE CANCEL:

IF YOU CHOOSE MODIFY:

You have now EXITED Library

Programming Mode and can

operate the controller. 

Содержание MERIDIAN Series

Страница 1: ...prior written authorization is strictly prohibited Toll Free Technical Support 24 Hours A Day 365 Days AYear from the U S Canada and the Caribbean 1 800 243 9271 the time is right www fastinc com 1 8...

Страница 2: ...efore installing this controller it should be verified that the ambient temperature at the mounting location does not exceed 158 F 70 C CLEANING THE CONTROLLER Using a clean damp cloth wipe down your...

Страница 3: ...haracter 14 segment Displays programming and cook cycle information 2 SERVICE WINDOW Locate the controller s serial number and tech support phone number easily 3 INDICATOR LIGHTS lit when there s an a...

Страница 4: ...iring the oil be filtered after x amount of times Any product key with Filter Lockout pro grammed will cease to operate until the oil is filtered A filter lockout cycle count valid range 0 to 99 can b...

Страница 5: ...unit starts to signal the product key being pressed is not pro grammed Stop a Cook Cycle Press and hold an active product key for 3 seconds Tim ing will stop Respond to a DONE Alarm Cancel the signal...

Страница 6: ...aintain a temperature of 190 F 88 C to allow the boil function to be performed To Enter Boil Mode Press and hold the P key for 3 sec onds COUNTS will be displayed Press the up or down arrow keys until...

Страница 7: ...count of all keys combined Press the P key again CLRGLOBL then NO will be displayed Use the left and right arrow keys to toggle between YES and NO Choose YES to reset your total product count or NO t...

Страница 8: ...splayed Stage timing mode 1 10 flex or straight is displayed Solenoid condition 1 10 open or close is displayed Action alarm status is displayed After fryer is filtered this display prompts you to ref...

Страница 9: ...t temperature will be displayed To change press toggle clear to change the temperature to zero Type in a new temperature using the prod uct keys Press the P key SETTIMING MODE Use the left and or righ...

Страница 10: ...ess the P key SET HOLDTIME Actual hold time will be displayed To change press toggle clear to change the time to zero Type in a new time using the prod uct keys Press the P key SET FILTER COUNT Actual...

Страница 11: ...nge the time to zero Type in a new time using the product keys Press the P key PROGRAM SETBACK TEMPERATURE Actual set temperature will be dis played To change press tog gle clear to change the tempera...

Страница 12: ...in 3 2 2 8 using the product keys Press the P key Press the down arrow key Press the down arrow key UNTIL Offset is displayed Press the P key Use the product keys to enter a new offset temperature to...

Страница 13: ...IBR Action Alarm Library by pressing the P key EXIT LIBRARY PRO GRAMMING Press the up or down arrow keys until dis play reads EXIT A flashing dash will be dis played Press the SCAN key and use the pro...

Страница 14: ...aker Replace controller Button Problem Frozen key Unplug controller Hold down the TOGGLE CLEAR key as you plug controller back in Inoperable key Replace controller PROBE is Displayed Defective tempera...

Страница 15: ...ST 10 18 Product Cooking Controllers Notes 15 This document contains confidential information The dissemination publication copying or duplication of this document or the software described herein wit...

Страница 16: ...tion and any labor costs for the replacement of probes will be made at your expense The FAST Exchange Program is available to any FAST Domestic Customer whose account is current and applies to all FAS...

Отзывы: