Operating Instructions

2

Notices

(FAST.) is not liable for any use of product not in accordance
with (FAST.)’s installation and operating instructions. 

Before using this equipment, or for any questions on the
operation of the appliance, consult and follow all instructions
and safety warnings found in the appliance operator’s manu-
al supplied from the manufacturer of the appliance. 

Not all features are available on some models. 

Controller
Operating
Environment

The solid state components in this controller are designed to operate reliably in a tem-
perature range up to 158°F/70°C. Before installing this controller, it should be verified
that the ambient temperature at the mounting location does not exceed 158°F/70°C. 

Cleaning the
Controller

Using a clean damp cloth, wipe down your controller daily using a commercial quali-
ty foodservice-approved detergent. 

Do not allow oil to build up on any part of the controller.

NEVER use chemical or abrasive cleaners on your controller. The controller’s
overlay may be damaged.

Содержание Meridian MEC-110

Страница 1: ...formation The dissemination publication copying or duplica tion of this document or the software described herein without prior written authorization is strict ly prohibited 229 51339 Rev A Printed in...

Страница 2: ...anu al supplied from the manufacturer of the appliance Not all features are available on some models Controller Operating Environment The solid state components in this controller are designed to oper...

Страница 3: ...splays programming and cook cycle information 2 SERVICE WINDOW Locate the controller s serial number and tech support phone number easily 3 INDICATOR LIGHTS lit when there s an active cook cycle and i...

Страница 4: ...ll adjust the actual cook time tak ing into consideration the temperature variation due to load size initial product temperature product moisture content and other factors affecting the cook cycle If...

Страница 5: ...nd the controller is ON it will control the melting of the oil Programmable Operating Mode The controller can be programmed to operate as either a controller or timer Programmable Pressure Valve The p...

Страница 6: ...is programmed the correct cooking time will be displayed and will immediately start to count down in minutes and seconds DONE will display when the cook cycle has ended The pressure solenoid will also...

Страница 7: ...xit Boil Mode press and hold the P key for 3 sec onds PROGRAM will be displayed Press the up or down arrow keys until BOIL is displayed then press the P key This will exit you from the boil mode If th...

Страница 8: ...he P key To Exit Product Counts COUNTS will be displayed Press the up arrow key EXIT will be displayed Press the P key The controller will exit programming mode Force A Filter To Force A Filter at any...

Страница 9: ...Programming Standby Mode Controller is in Fahrenheit or Celsius Programming Mode Controller is in Appliance Type Programming Mode Display Descriptions Controller is in Operating Mode Actual vat tempe...

Страница 10: ...3 seconds Type in 1 7 2 4 using the prod uct keys Press the P key Press the down arrow key Press the P key Press the P key All product key LEDs will light up PROGRAM A PRODUCT KEY Press the product ke...

Страница 11: ...key to either go to next action alarm name or continue through programming SET ACTION ALARM CANCEL MODE ALMCNCL1 will be displayed then the action alarm mode Use the left and right arrow keys to choos...

Страница 12: ...SET WEIGHT WEIGHT will be displayed then a number To change press toggle clear to change the number to zero Type in a new weight 1 99 using the product keys Press the P key to continue EXIT PROGRAMMIN...

Страница 13: ...ess the P key SET TONE VOLUME Use the left and or right arrow keys to choose 1 2 3 4 or NONE Press the P key SET TEMPERATURE SCALE Use the left and or right arrow keys to choose Fahrenheit F or Celsiu...

Страница 14: ...LTER COUNT Actual filter count will be shown 0 999 based on pieces or pounds To change press toggle clear to change the count to zero Type in a new filter count using the product keys Press the P key...

Страница 15: ...new time using the prod uct keys 0 99 99 Press the P key EXIT SYSTEM PRO GRAMMING MODE Press the up arrow key Press the P key You have now EXITED System Programming Mode and can operate the controller...

Страница 16: ...Programming Custom Product and Action Alarm Names to the Library ENTER LIBRARY PRO GRAMMING MODE Press and hold the P key for 3 seconds Type in 3 2 2 8 using the prod uct keys Press the P key Press th...

Страница 17: ...til dis play reads EXIT TO CANCEL OR MODIFY WORD press the left or right arrow keys to select CANCEL or MODIFY Press the P key to EXIT and can cel the word Press the SCAN key to go back and modify the...

Страница 18: ...troller Button Problem Frozen key Unplug controller Hold down the TOGGLE CLEAR key as you plug controller back in Inoperable key Replace controller PROBE is Displayed Defective temperature probe Repla...

Страница 19: ...rogramming Mode 10 Exit Programming Mode 11 Filter Count 12 Hold Time 11 Hold Time Mode 12 Product Display Name 10 Product Key 10 Sensitivity 12 Timing Mode 11 Weight 12 Programming SYSTEM Store Manag...

Страница 20: ...hnician Monday through Friday 8am 5pm EST by going to www fastinc com selecting the Support link at the top of the page and clicking on Email Us Free Program for Service Exchanges FAST provides an Exc...