6. EtherCAT Object Dictionary
6.5.13
Object 6065h: Following error window
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
6065h
0
Following error window
U32
RW
Yes
No
5000
Set the range of Follow Error Value.
Information
This object can NOT be set while it’s ’Operation Enabled’ state. Please set after ’Operation Disable’.
Please refer to
If the value of Following error actual value is greater than the value of Following error window, ’FF03h -
Position Tracking Error’ or ’FF0Fh - Position Overflow Error’ alarm occurs and Drive is in Fault state.
6.5.14
Object 6067h: Position window
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
6067h
0
Position window
U32
RW
Yes
No
0
∼
63
0
Set the range of Positioning value.
Information
This object can NOT be set while it’s ’Operation Enabled’ state. Please set after ’Operation Disable’.
Please refer to
6.5.15
Object 606Bh: Velocity demand value
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
606Bh
0
Velocity demand value
I32
RO
No
TxPDO
0
This object indicates internal command velocity. The velocity value is a positive value when the motor
rotates in the positive direction, and a negative value when the motor rotates in the negative direction.
Information
This object is supported only in Profile Position Mode and Homing Mode. 0 value is displayed in
Cyclic Synchronous Position Mode.
6.5.16
Object 606Ch: Velocity actual value
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
606Ch
0
Velocity actual value
I32
RO
No
TxPDO
0
This object indicates internal command velocity. The velocity value is a positive value when the motor
rotates in the positive direction, and a negative value when the motor rotates in the negative direction.
Information
This object does not display current actual velocity. it displays the same value as the value of
Velocity demand value.
6.5.17
Object 607Ah: Target position
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
607Ah
0
Target position
I32
RW
No
RxPDO
-2147483648
∼
2147483647
0
This object sets target position under Profile Position Mode, Cyclic Synchronous Position Mode.
Rev.37
FASTECH Co., Ltd.
85
Содержание Ezi-SERVOII
Страница 1: ...Closed Loop Stepping System EtherCAT Network User Manual Ezi SERVOII EtherCAT TO FASTECH Co Ltd...
Страница 10: ...Chapter 1 Product Specification Rev 37 FASTECH Co Ltd 10...
Страница 12: ...1 Product Specification 1 2 Product Dimension Figure 1 2 Dimensions Rev 37 FASTECH Co Ltd 12...
Страница 15: ...Chapter 2 Installation Rev 37 FASTECH Co Ltd 15...
Страница 17: ...2 Installation 2 2 System Configuration Figure 2 1 System Configuration Diagram Rev 37 FASTECH Co Ltd 17...
Страница 18: ...2 Installation 2 3 External Wiring Diagram Figure 2 2 External Wiring Diagram Rev 37 FASTECH Co Ltd 18...
Страница 29: ...Chapter 3 EtherCAT Communication Rev 37 FASTECH Co Ltd 29...
Страница 35: ...Chapter 4 CiA402 Drive Profile Rev 37 FASTECH Co Ltd 35...
Страница 67: ...Chapter 5 Operation Rev 37 FASTECH Co Ltd 67...
Страница 71: ...Chapter 6 EtherCAT Object Dictionary Rev 37 FASTECH Co Ltd 71...