4. CiA402 Drive Profile
4.3
Mode of operation
Currently activated Mode of operation display (6061h) decides the action of controller. Meaning for some
bits of Control word (6040h) and Status word (6041h) Objects can be decided by Mode of operation
display (6061h).
Able to set selected operation mode by Mode of operation (6060h). Currently activated operation mode
can be checked by Mode of operation display (6061h).
Operation modes supported by current controller are as follows.
Mode of operation
Description
Abbreviation
1
Profile Position Mode
PP
6
Homing Mode
HM
8
Cyclic Synchronous Position Mode
CSP
Table 4.11: Supported Operation Modes